                                                                                                               AN619
Manually Generating an Si5351 Register Map for 10-MSOP and
20-QFN Devices


1. Introduction
The Si5351 is a highly flexible and configurable clock generator and VCXO. A block diagram of the Si5351
programmable clock IC is shown in Figure 1. To support this flexibility, Skyworks Solutions has created
ClockBuilder Pro to create register maps automatically and easily for a given configuration. Since programming
with ClockBuilder Pro may not always be well suited for every system’s requirements, this document presents the
procedures and equations for determining a complete register set from a frequency plan for any 10-MSOP or 20-
QFN Si5351 device. Section 2 highlights the overall frequency plan algorithm, and sections 3 and beyond detail all
the necessary register calculations.




                                    Figure 1. Generalized Si5351 Block Diagram
Figure 1 is a generalized block diagram of the Si5351. The Si5351 is available in three variants:
  Si5351A—XTAL only device.
  Si5351B—XTAL + VCXO.
  Si5351C—XTAL + CLKIN.
If spread spectrum is turned on, it is supported by PLLA.
VCXO functionality (Si5351B devices only) is supported by PLLB.
The Si5351 can also come in three package types: 10-MSOP, 20-QFN, and 16-QFN. This document only covers
the programming of 10-MSOP and 20-QFN devices. For more information on programming a 16-QFN device, see
AN1234.




         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619
2. Conceptualizing a Frequency Plan
The device consists of two PLLs—PLLA and PLLB. Each PLL generates an intermediate VCO frequency in the
range of 600 to 900 MHz using a Feedback Multisynth. These VCO frequencies can then be divided down by
individual output Multisynth dividers to generate any frequency between 500 kHz and 200 MHz. Additionally, the R
dividers can be used to generate any output frequency down to 2.5 kHz. The relationship between the VCO and
output frequencies is given below.
                                                                                       fvco
                                                 fout x = ---------------------------------------------------------------------
                                                          Output_Multisynth x  R x


                                                fvco = fin  Feedback_Multisynth

Use the steps in the sections below to draw out a conceptual frequency plan map.

2.1. PLL Selection
If spread spectrum is not enabled, either of the two PLLs may be used as the source for any outputs of the
Si5351A. If both XTAL and CLKIN input options are used simultaneously (Si5351C only), then one PLL must be
reserved for use with CLKIN and one for use with the XTAL.
Note: PLLA must be used for any spread spectrum-enabled outputs. PLLB must be used for any VCXO outputs.
2.1.1. Selecting the Proper VCO Frequencies and Divide Ratios
The general criteria below may be used to set the VCO frequencies. This is a general model, and individual
applications may require some modification.
     1. Valid Multisynth divider ratios are 4, 6, 8, and any fractional value between 8 + 1/1,048,575 and 2048. This
        means that if any output is greater than 112.5 MHz (900 MHz/8), then this output frequency sets one of the
        VCO frequencies.
     2. For the frequencies where jitter is a concern make the output Multisynth divide ratio an integer. If possible,
        make both output and feedback Multisynth ratios integers.
     3. Once criteria 1 and 2 are satisfied, try to select as many integer output Multisynth ratios as possible.

2.2. Output Clock Pin Assignment (Optional)
Some customers may wish to have full control of output clock pin assignment. The guidelines below may be used
to assign clocks to pins on the device.
     1. Equal output frequencies should share a VDDO bank (e.g., CLK0&1, CLK2&3, etc.) whenever possible in
        order to ensure minimal jitter due to PCB crosstalk.
     2. Isolate unique output frequencies on individual VDDO bank if possible. For example, if the four outputs are
        25 MHz, 25 MHz, 27 MHz, and 74.25 MHz, then place them on CLK0, CLK1, CLK2, and CLK4,
        respectively.
     3. Otherwise, use all necessary CLK channels based on the required frequency plan.
Note: The only valid divide ratios for CLK6 and CLK7 Multisynth dividers are even integers between 6 and 254 inclusive. This
      may limit the two VCO frequencies if all 8 output clocks are used.




2         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619
3. Configuring Input and PLL Register Parameters (Synthesis Stage 1)
This section describes register parameters related to the input reference and the two PLLs.

3.1. PLL Input Source
The input source for each PLL must be selected. For the Si5351A and Si5351B devices, the only possible source
is the XTAL, but for the Si5351C device, each PLL can be synchronized to either an XTAL or a CMOS clock on the
CLKIN pin.
3.1.1. XTAL Source
If the source for the PLL is a crystal, PLLx_SRC must be set to 0 in register 15. XTAL_CL[1:0] must also be set to
match the crystal load capacitance (see register 183).
3.1.2. CMOS Clock Source
If a PLL needs to be synchronized to a CMOS clock, PLLx_SRC must be 1. The input frequency range of the PLL
is 10 to 40 MHz. If CLKIN is > 40 MHz, the CLKIN input divider must be used to bring the PLL input within the 10–
40 MHz range. See CLKIN_DIV[1:0], register 15, bits [7:6].

3.2. Feedback Multisynth Divider Equations
Once the input source for each PLL and (if necessary) CLKIN_DIV are determined, the two VCO frequencies
selected in Section 2 above can be generated using the following equations. Each feedback divider essentially
multiplies the source frequency such that


                                                         f VCO = f XTAL   a + b
                                                                                 -- 
                                                                                 c
                            and/or

                                                                   f CLKIN                            b
                                                   f VCO = ---------------------------------   a + -- 
                                                           CLKIN_DIV                                  c
The fractional ratio
                                                                          a+b
                                                                            --
                                                                            c
has a valid range of 15 + 0/1,048,575 and 90 and is represented in the Si5351 register space using the equations
below.
                                                                                   b
                                       MSNx_P1  17:0  = 128  a + Floor  128  --  – 512
                                                                                   c


                                                                                       b
                                        MSNx_P2  19:0  = 128  b – c  Floor  128  -- 
                                                                                      c



                                                          MSNx_P3  19:0  = c


In the equations above, x is used to represent MSNA and MSNB, the PLLA and PLLB Multisynth dividers
respectively. The equations above must be repeated for Multisynths MSNA and MSNB. As mentioned earlier in
Section “2.1. PLL Selection”, spread spectrum is only supported by PLLA, and the VCXO functionality is only
supported by PLLB. When using the VCXO function, set the MSNB divide ratio a + b/c such that c = 106. This must
be taken into consideration when configuring a frequency plan.
3.2.1. Integer Divide Values (FBx_INT)
If a + b/c is an even integer, integer mode may be enabled for PLLA or PLLB by setting parameter FBA_INT or
FBB_INT respectively. In most cases setting this bit will improve jitter when using even integer divide values.
Whenever spread spectrum is enabled, FBA_INT must be set to 0.

         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com             3
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619
4. Configuring the Output Register Parameters
This section covers the Multisynth and output driver settings necessary for each output. As shown in Figure 2, one
of the two VCO frequencies is divided down by each Multisynth divider. This is followed by an output driver state.
See “4.2. Output Driver Settings”.


                                                                                          XO
                                                                                          CLKIN
                                                                                                   ÷R0            CLK0
                                                      VCOA
                                                                       Multisynth0         M0
                                                      VCOB               ÷M0

                                                                                          XO
                                                                                          CLKIN
                                                                                                   ÷R1            CLK1
                                                                                           M0
                                                      VCOA
                                                                       Multisynth1         M1
                                                      VCOB               ÷M1

                                                                                          XO
                                                                                          CLKIN
                                                                                                                  CLK2
                                                                                           M0      ÷R2
                                                      VCOA
                                                                       Multisynth2         M2
                                                      VCOB               ÷M2

                                                                                          XO
                                                                                          CLKIN
                                                                                                   ÷R3            CLK3
                   XO                                                                      M0
                                    PLLA      VCOA
                   CLKIN             NA                                Multisynth3         M3
                                                      VCOB               ÷M3

                                                                                          XO
                                                                                          CLKIN
                                                                                                                  CLK4
                                                                                                   ÷R4
                                                      VCOA
                   XO                                                  Multisynth4         M4
                                    PLLB      VCOB                       ÷M4
                   CLKIN             NB
                                                                                          XO
                                                                                          CLKIN
                                                                                                                  CLK5
                                                                                           M4      ÷R5
                                                      VCOA
                                                                       Multisynth5         M5
                                                      VCOB               ÷M5

                                                                                          XO
                                                                                          CLKIN
                                                                                                   ÷R6            CLK6
                                                                                           M4
                                                      VCOA
                                                                       Multisynth6         M6
                                                      VCOB               ÷M6*

                                                                                          XO
                                                                                          CLKIN
                                                                                                                  CLK7
                                                                                           M4      ÷R7
                                                      VCOA
                                                                       Multisynth7         M7
                                                      VCOB               ÷M7*

                  * Multisynth 6 and 7 divide ratios can only be even integers between6 and 254.


                           Figure 2. Detailed Dividers and Output Drivers Block Diagram


4         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619
4.1. Output Multisynth Settings (Synthesis Stage 2)
This section describes the settings related to the individual Multisynths. The Si5351 consists of six fractional
Multisynth divides (MS0-MS5) and two even-integer dividers (MS6 and MS7).
4.1.1. Output Multisynth Source (MSx_SRC)
Each of these dividers can be set to use PLLA or PLLB as its reference by setting MSx_SRC to 0 or 1 respectively.
See bit 5 description of registers 16-23.
4.1.2. Output Multisynth Divider Equations (Fout <= 150 MHz)
Once the PLL source for the output Multisynth is selected, the divide ratio can be set using the equations below.
Divider represented as fractional number,
                                                                 a+b
                                                                   --
                                                                   c
between 8 + 1/1,048,575 and 2048.
                                                                                   b
                                        MSx_P1  17:0  = 128  a + Floor  128  --  – 512
                                                                                   c

                                                                                       b
                                         MSx_P2  19:0  = 128  b – c  Floor  128  -- 
                                                                                      c


                                                        MSx_P3  19:0  = c
In the equations above, x=0, 1, ...5. As previously noted, MS6 and MS7 are integer-only dividers. The valid range
of values for these dividers is all even integers between 6 and 254 inclusive. For MS6 and MS7, set MSx_P1
directly (e.g., MSx_P1=divide value).
4.1.2.1. Integer Divide Values(MSx_INT)
If any of the MS0-MS5 is an even integer, Multisynth integer mode may be enabled by setting MSx_INT=1 (see
registers 16-21, bit 6). In most cases setting this bit will improve jitter when using even integer divide values.
Multisynths 6 and 7 inherently operate in integer mode, and so there is no register to turn integer mode on or off.
However, it's important to note that Multisynth integer mode cannot be used when adding phase offsets in NVM. In
other words, MSx_INT needs to be set to 0 if phase offsets need to be enabled.
4.1.3. Output Multisynth Divider Equations (150 MHz <Fout<=200 MHz)
Output frequencies greater than 150 MHz are available on Multisynths 0-5. For this frequency range a divide value
of 4 must be used by setting
  MSx_P1=0,
  MSx_P2=0,
  MSx_P3=1,
  MSx_INT=1, and
  MSx_DIVBY4[1:0]=11b.
Set the appropriate feedback Multisynth to generate fVCO=Fout*4.

4.2. Output Driver Settings
Once the Multisynth registers are assembled, the output driver settings can be modified according to the
information in this section.
4.2.1. Clock Source (CLKx_SRC)
Generally, Multisynth x should be output on CLKx, however XO, CLKIN, or a divided version of either (see section
4.2.2 on R dividers) may also be output on each of the CLKx pins. Additionally, MS0 (or a divided version of MS0)
may be output on CLK0-CLK3, and MS4 (or a divided version of MS4) may be output on CLK4-CLK7. See
CLKx_SRC description for details.




         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com             5
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619
4.2.2. R Dividers
The R dividers can be used to generate frequencies below about 500 kHz. Each individual output R divider can be
set to 1, 2, 4, 8,....128 by writing the proper setting for Rx_DIV. Set this parameter to generate frequencies down to
8kHz.
4.2.3. (CLKx_INV)
In some cases, the user may need to invert the polarity (i.e., 180° phase offset) of one or more outputs with respect
to the other outputs. This is achieved by setting CLKx_INV=1.
4.2.4. (CLKx_DIS_STATE)
When a clock is disabled via the OEB pin or OEB control register (reg 3), the output driver may be set to present a
logic low, logic high, or high-impedance at the device pin. See CLKx_DIS_STATE description for details.
4.2.5. Unused Clock Outputs
Any unused clock outputs may be powered down to reduce IDDO current consumption. Set CLKx_PDN=1 to
power down unused clock output drivers.
In the case of the 3-output 10-MSOP Si5351, only CLK0, 1, and 2 are used. The remaining clock outputs should be
powered down to conserve power. This will be done automatically for any project created in ClockBuilder Pro.
However, this will need to be done manually when programming a blank Si5351A-B-GT completely by hand,
without the use of ClockBuilder Pro.




6         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                                     AN619
5. Configuring Spread Spectrum Register Parameters
Spread spectrum can be enabled on any Multisynth output that uses PLLA as its reference. Valid ranges for spread
spectrum include –0.1% to –2.5% down spread and up to ± 1.5% center spread. This spread modulation rate is
fixed at approximately 31.5 kHz.
The following parameters must be known to properly set up spread spectrum:
  fPFD(A) input frequency to PLLA in Hz (determined in Sec 2 above and referred to in “3.1.2. CMOS Clock
     Source”). This is also listed in the ClockBuilder Pro generated register map file as “#PFD(MHz)=...”
  a + b/c PLLA Multisynth ratio (determined in Sec 2 above).
  sscAMPSpread amplitude (e.g., for down or center spread amplitude of 1%, sscAmp = 0.01).
Use the equations below to set up the desired spread spectrum profile.
Note: Make sure MSNA is set up in fractional mode when using the spread spectrum feature. See parameter FBA_INT in reg-
      ister 22.

5.1. Down Spread
For down spread, four spread spectrum parameters need to be written: SSUDP[11:0], SSDN_P1[11:0],
SSDN_P2[14:0], and SSDN_P3[14:0].
Up/Down Parameter:
                                                                                      f PFD
                                                   SSUDP  11:0  = Floor  ---------------------------- 
                                                                             4  31 500
Intermediate Equation (no register writes):


                                                                                      sscAmp
                                        SSDN = 64   a + b
                                                          --   -----------------------------------------------------------------
                                                         c  1 + sscAmp   SSUDP

Down-Spread Parameters:
                                                     SSDN_P1  11:0  = Floor  SSDN 


                                       SSDN_P2  14:0  = 32 767   SSDN – SSDN_P1 


                                                SSDN_P3  14:0  = 32 767 = 0x7FFF
Up-Spread Parameters:
                                                                      SSUP_P1 = 0


                                                                      SSUP_P2 = 0


                                                                      SSUP_P3 = 1




         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com             7
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619
5.2. Center Spread
For center spread, seven spread spectrum parameters need to be written: SSUDP[11:0], SSDN_P1[11:0],
SSDN_P2[14:0], SSDN_P3[14:0], SSUP_P1[11:0], SSUP_P2[14:0], and SSUP_P3[14:0].
Up/Down Parameter:
                                                                                       f PFD
                                                     SSUDP  11:0  = Floor  ---------------------------- 
                                                                             4  31 500

Intermediate Equations (no register writes):
                                                                                        sscAmp
                                         SSUP = 128   a + b
                                                            --   -----------------------------------------------------------------
                                                           c  1 – sscAmp   SSUDP


                                                                                          sscAmp
                                         SSDN = 128   a + b
                                                             --   -----------------------------------------------------------------
                                                             c        1 + sscAmp   SSUDP
Up-Spread Parameters:
                                                       SSUP_P1  11:0  = Floor  SSUP 


                                        SSUP_P2  14:0  = 32 767   SSUP – SSUP_P1 


                                                  SSUP_P3  14:0  = 32 767 = 0x7FFF
Down-Spread Parameters:
                                                       SSDN_P1  11:0  = Floor  SSDN 


                                        SSDN_P2  14:0  = 32 767   SSDN – SSDN_P1 


                                                   SSDN_P3  14:0  = 32767 = 0x7FFF

5.3. Spread Spectrum Enable Pin (SSEN)
The Spread Spectrum Enable control pin is available on the Si5351A and B devices. Spread spectrum enable
functionality is a logical OR of the SSEN pin and SSC_EN register bit, so for the SSEN pin to work properly, the
SSC_EN register bit must be set to 0.




8         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619
6. Configuring Initial Phase Offset Register Parameters
Outputs 0-5 of the Si5351 can be programmed with an independent initial phase offset. The phase offset only
works when MS0-5 are set as fractional dividers (divider values greater than 8). The phase offset parameter is an
unsigned integer where each LSB represents a phase difference of a quarter of the VCO period, TVCO/4. Use the
equation below to determine the register value. Also, remember that any divider using the phase offset feature
needs the MSx_INT bit set to 0.


                                CLKx_PHOFF  4:0  = Round  DesiredOffset  sec   4  F VCO 


7. Configuring VCXO Parameters (Si5351 B only)
The Si5351B combines free-running clock generation and a VCXO in a single package. The VCXO architecture of
the Si5350B eliminates the need for an external pullable crystal. The “pulling” is done at PLLB. Only a standard,
low cost, fixed-frequency (25 or 27 MHz) AT-cut crystal is required and is used as the reference source for both
PLLA and PLLB.
PLLB must be used as the source for any VCXO output clock. Feedback B Multisynth divider ratio must be set
such that the denominator, c, in the fractional divider a + b/c is fixed to 106. Set VCXO_Param register value
according to the equation below. Note that 1.03 is a margining factor to ensure the full desired pull range is
achieved. For a desired pull-range of +/– 30 ppm, the value APR in the equation below is 30, for +/– 60 ppm APR
is 60, and so on.

                                                                           b  APR
                                       VCXO_Param[21:0] = 1.03  128a + --------
                                                                               6
                                                                        10




         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com             9
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619
8. Si5351 Registers
This section describes the registers and their usage in detail. These values are easily configured using
ClockBuilder Pro.

8.1. Register Map Summary
The following is a summary of the register map used to read status, control, and configure the Si5351.

Register         7                 6                5               4                 3                     2                    1                    0
   0         SYS_INIT          LOL_B           LOL_A          LOS_CLKIN         LOS_XTAL              Reserved                         REVID[1:0]
   1         SYS_INIT_        LOL_B_           LOL_A_         LOS_CLKIN_       LOS_XTAL_                                   Reserved
               STKY            STKY             STKY             STKY            STKY
   2         SYS_INIT_        LOL_B_          LOL_A _         LOS_CLKIN-       LOS_XTAL_                                   Reserved
               MASK            MASK            MASK             MASK             MASK
   3         CLK7_OEB        CLK6_OEB        CLK5_OEB         CLK4_OEB          CLK3_OEB             CLK2_OEB             CLK1_OEB             CLK0_OEB
  4–8                                                                      Reserved
   9        OEB_MASK7       OEB_MASK6       OEB_MASK5         OEB_MASK4        OEB_MASK3            OEB_MASK2            OEB_MASK1            OEB_MASK0
 10–14                                                                     Reserved
  15              CLKIN_DIV[1:0]                        Reserved                PLLB_SRC             PLLA_SRC                           Reserved
  16         CLK0_PDN         MS0_INT         MS0_SRC          CLK0_INV                   CLK0_SRC[1:0]                              CLK0_IDRV[1:0]
  17         CLK1_PDN         MS1_INT         MS1_SRC          CLK1_INV                   CLK1_SRC[1:0]                              CLK1_IDRV[1:0]
  18         CLK2_PDN         MS2_INT         MS2_SRC          CLK2_INV                   CLK2_SRC[1:0]                              CLK2_IDRV[1:0]
  19         CLK3_PDN         MS3_INT         MS3_SRC          CLK3_INV                   CLK3_SRC[1:0]                              CLK3_IDRV[1:0]
  20         CLK4_PDN         MS4_INT         MS4_SRC          CLK4_INV                   CLK4_SRC[1:0]                              CLK4_IDRV[1:0]
  21         CLK5_PDN         MS5_INT         MS5_SRC          CLK5_INV                   CLK5_SRC[1:0]                              CLK5_IDRV[1:0]
  22         CLK6_PDN         FBA_INT         MS6_SRC          CLK6_INV                   CLK6_SRC[1:0]                              CLK6_IDRV[1:0]
  23         CLK7_PDN         FBB_INT         MS6_SRC          CLK7_INV                   CLK7_SRC[1:0]                              CLK7_IDRV[1:0]
  24           CLK3_DIS_STATE[1:0]             CLK2_DIS_STATE[1:0]                    CLK1_DIS_STATE[1:0]                       CLK0_DIS_STATE[1:0]
  25           CLK7_DIS_STATE[1:0]             CLK6_DIS_STATE[1:0]                    CLK5_DIS_STATE[1:0]                       CLK4_DIS_STATE[1:0]
  26                                                                    MSNA_P3[15:8]
  27                                                                    MSNA_P3[7:0]
  28                                                     Reserved                                                                    MSNA_P1[17:16]

  29                                                                    MSNA_P1[15:8]
  30                                                                    MSNA_P1[7:0]
  31                               MSNA_P3[19:16]                                                           MSNA_P2[19:16]

  32                                                                    MSNA_P2[15:8]
  33                                                                    MSNA_P2[7:0]
  34                                                                    MSNB_P3[15:8]
  35                                                                    MSNB_P3[7:0]

  36                                                     Reserved                                                                    MSNB_P1[17:16]

  37                                                                    MSNB_P1[15:8]
  38                                                                    MSNB_P1[7:0]
  39                               MSNB_P3[19:16]                                                           MSNB_P2[19:16]
  40                                                                    MSNB_P2[15:8]
  41                                                                    MSNB_P2[7:0]
  42                                                                    MS0_P3[15:8]
  43                                                                     MS0_P3[7:0]
  44                                         R0_DIV[2:0]                                  MS0_DIVBY4[1:0]                            MS0_P1[17:16]
  45                                                                    MS0_P1[15:8]
  46                                                                     MS0_P1[7:0]
  47                               MS0_P3[19:16]                                                                MS0_P2[19:16]
  48                                                                    MS0_P2[15:8]
  49                                                                     MS0_P2[7:0]




10        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                                    AN619
Register         7               6               5             4                  3                     2                   1                   0
  50                                                                MS1_P3[15:8]
  51                                                                MS1_P3[7:0]
  52                                        R1_DIV[2:0]                               MS1_DIVBY4[1:0]                           MS1_P1[17:16]
  53                                                                MS1_P1[15:8]
  54                                                                MS1_P1[7:0]
  55                             MS1_P3[19:16]                                                              MS1_P2[19:16]
  56                                                                MS1_P2[15:8]
  57                                                                MS1_P2[7:0]
  58                                                                MS2_P3[15:8]
  59                                                                MS2_P3[7:0]
  60                                        R2_DIV[2:0]                               MS2_DIVBY4[1:0]                           MS2_P1[17:16]
  61                                                                MS2_P1[15:8]
  62                                                                MS2_P1[7:0]
  63                             MS2_P3[19:16]                                                              MS2_P2[19:16]
  64                                                                MS2_P2[15:8]
  65                                                                MS2_P2[7:0]
  66                                                                MS3_P3[15:8]
  67                                                                MS3_P3[7:0]
  68                                        R3_DIV[2:0]                               MS3_DIVBY4[1:0]                           MS3_P1[17:16]
  69                                                                MS3_P1[15:8]
  70                                                                MS3_P1[7:0]
  71                             MS3_P3[19:16]                                                              MS3_P2[19:16]
  72                                                                MS3_P2[15:8]
  73                                                                MS3_P2[7:0]
  74                                                                MS4_P3[15:8]
  75                                                                MS4_P3[7:0]
  76                                        R4_DIV[2:0]                               MS4_DIVBY4[1:0]                           MS4_P1[17:16]
  77                                                                MS4_P1[15:8]
  78                                                                MS4_P1[7:0]
  79                             MS4_P3[19:16]                                                              MS4_P2[19:16]
  80                                                                MS4_P2[15:8]
  81                                                                MS4_P2[7:0]
  82                                                                MS5_P3[15:8]
  83                                                                MS5_P3[7:0]
  84                                        R5_DIV[2:0]                               MS5_DIVBY4[1:0]                           MS5_P1[17:16]
  85                                                                MS5_P1[15:8]
  86                                                                MS5_P1[7:0]
  87                             MS5_P3[19:16]                                                              MS5_P2[19:16]
  88                                                                MS5_P2[15:8]
  89                                                                MS5_P2[7:0]
  90                                                                MS6_P1[7:0]
  91                                                                MS7_P1[7:0]
  92          Reserved                      R7_DIV[2:0]                     Reserved                                  R6_DIV[2:0]
  149         SSC_EN                                                        SSDN_P2[14:8]

  150                                                               SSDN_P2[7:0]

  151       SSC_MODE                                                        SSDN_P3[14:8]
  152                                                               SSDN_P3[7:0]

  153                                                               SSDN_P1[7:0]
  154                             SSUDP[11:8]                                                               SSDN_P1[11:8]

  155                                                                SSUDP[7:0]
  156                                                                       SSUP_P2[14:8]




          Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com            11
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619
Register         7                 6              5            4                  3                  2                   1        0
  157                                                                SSUP_P2[7:0]
  158                                                                        SSUP_P3[14:8]
  159                                                                SSUP_P3[7:0]
  160                                                                SSUP_P1[7:0]
  161                              SS_NCLK[3:0]                                                          SSUP_P1[11:8]

  162                                                              VCXO_Param[7:0]
  163                                                              VCXO_Param[15:8]
  164                Reserved                                                         VCXO_Param[21:16]
  165         Reserved                                                     CLK0_PHOFF[6:0]
  166         Reserved                                                     CLK1_PHOFF[6:0]

  167         Reserved                                                     CLK2_PHOFF[6:0]
  168         Reserved                                                     CLK3_PHOFF[6:0]

  169         Reserved                                                     CLK4_PHOFF[6:0]

  170         Reserved                                                     CLK5_PHOFF[6:0]


171–176                                                                Reserved
  177        PLLB_RST           Reserved    PLLA_RST                                              Reserved
178–182                                                                Reserved
  183                XTAL_CL                                                              Reserved
184–186                                                                Reserved
  187        CLKIN_FA-           XO_FA-      Reserved       MS_FA-                                         Reserved
             NOUT_EN            NOUT_EN                    NOUT_EN
188-255                                                                Reserved




12        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619
9. Register Descriptions

Register 0. Device Status


  Bit           D7             D6              D5               D4               D3              D2              D1             D0

 Name      SYS_INIT          LOL_B           LOL_A        LOS_CLKIN LOS_XTAL                 Reserved              REVID[1:0]

 Type           R               R               R                R                R              R                       R

Reset value = 0000 0000

 Bit         Name                                                            Function
  7        SYS_INIT          System Initialization Status.
                             During power up the device copies the content of the NVM into RAM and performs a sys-
                             tem initialization. The device is not operational until initialization is complete. It is not rec-
                             ommended to read or write registers in RAM through the I2C interface until initialization is
                             complete. An interrupt will be triggered (INTR pin = 0, Si5351C only) during the system
                             initialization period.
                             0: System initialization is complete. Device is ready.
                             1: Device is in system initialization mode.
  6          LOL_B           PLLB Loss Of Lock Status.
                             Si5351A/C only. PLLB will operate in a locked state when it has a valid reference from
                             CLKIN or XTAL. A loss of lock will occur if the frequency of the reference clock forces the
                             PLL to operate outside of its lock range or if the reference clock fails to meet the minimum
                             requirements of a valid input signal as specified in the Si5351 data sheet. An interrupt will
                             be triggered (INTR pin = 0, Si5351C) during a LOL condition.
                             0: PLL B is locked.
                             1: PLL B is unlocked. When the device is in this state it will trigger an interrupt causing the
                             INTR pin to go low (Si5351C only).
  5          LOL_A           PLL A Loss Of Lock Status.
                             PLL A will operate in a locked state when it has a valid reference from CLKIN or XTAL. A
                             loss of lock will occur if the frequency of the reference clock forces the PLL to operate out-
                             side of its lock range as specified in the data sheet, or if the reference clock fails to meet
                             the minimum requirements of a valid input signal as specified in the Si5351 data sheet. An
                             interrupt will be triggered (INTR pin = 0, Si5351C only) during a LOL condition.
                             0: PLL A is operating normally.
                             1: PLL A is unlocked. When the device is in this state it will trigger an interrupt causing the
                             INTR pin to go low (Si5351C only).
  4       LOS_CLKIN          CLKIN Loss Of Signal (Si5351C Only).
                             A loss of signal status indicates if the reference clock fails to meet the minimum require-
                             ments of a valid input signal as specified in the Si5351 data sheet. An interrupt will be trig-
                             gered (INTR pin = 0, Si5351C only) during a LOS condition.
                             0: Valid clock signal at the CLKIN pin.
                             1: Loss of signal detected at the CLKIN pin.




         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com            13
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619
  3        LOS_XTAL           Crystal Loss of Signal
                              A loss of signal status indicates that the crystal failed to meet the minimum requirements
                              of a valid input signal as specified in the Si5351 datasheet. This bit going high will trigger
                              an interrupt (INTR pin = 0) on a Si5351C device.
                              0: Valid crystal signal at the XA and XB Pins
                              1: Loss of crystal signal detected
  2         Reserved          Leave as default.
 1:0       REVID[1:0]         Revision number of the device.




14        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                        AN619

Register 1. Interrupt Status Sticky


   Bit              D7                    D6                 D5                 D4                  D3             D2      D1      D0

 Name       SYS_INIT_STKY LOL_B_STKY LOL_A_STKY                            LOS_-                LOS_
                                                                         CLKIN_STKY           XTAL_STKY

  Type             R/W                   R/W                R/W                R/W                 R/W            R/W     R/W     R/W

Reset value = 0000 0000

 Bit            Name                                                           Function

  7       SYS_INIT_STKY          System Calibration Status Sticky Bit.
                                 The SYS_INIT_STKY bit is triggered when the SYS_INIT bit (register 0, bit 7) is trig-
                                 gered high. It remains high until cleared. Writing a 0 to this register bit will cause it to
                                 clear.
                                 0: No SYS_INIT interrupt has occurred since it was last cleared.
                                 1: A SYS_INIT interrupt has occurred since it was last cleared.

  6        LOL_B_STKY            PLLB Loss Of Lock Status Sticky Bit.
                                 The LOL_B_STKY bit is triggered when the LOL_B bit (register 0, bit 6) is triggered
                                 high. It remains high until cleared. Writing a 0 to this register bit will cause it to clear.
                                 0: No PLL B interrupt has occurred since it was last cleared.
                                 1: A PLL B interrupt has occurred since it was last cleared.

  5        LOL_A_STKY            PLLA Loss Of Lock Status Sticky Bit.
                                 The LOL_A_STKY bit is triggered when the LOL_A bit (register 0, bit 5) is triggered
                                 high. It remains high until cleared. Writing a 0 to this register bit will cause it to clear.
                                 0: No PLLA interrupt has occurred since it was last cleared.
                                 1: A PLLA interrupt has occurred since it was last cleared.

  4      LOS_CLKIN_STKY CLKIN Loss Of Signal Sticky Bit (Si5351C Only).
                                 The LOS_CLKIN_STKY bit is triggered when the LOS_CLKIN bit (register 0, bit 4) is
                                 triggered high. It remains high until cleared. Writing a 0 to this register bit will cause it
                                 to clear.
                                 0: No LOS_CLKIN interrupt has occurred since it was last cleared.
                                 1: A LOS_CLKIN interrupt has occurred since it was last cleared.

  3      LOS_XTAL_STKY Crystal Loss of Signal Sticky Bit
                                 The LOS_XTAL_STKY bit is triggered when the LOS_XTAL bit (register 0, bit 3) is
                                 triggered high. It remains high until cleared. Writing a 0 to this register bit will cause it
                                 to clear.
                                 0: No LOS_XTAL interrupt has occurred since it was last cleared.
                                 1: A LOS_XTAL interrupt has occurred since it was last cleared.

 2:0          Reserved           Leave as default.




         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com            15
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619

Register 2. Interrupt Status Mask


   Bit               D7                    D6                  D5                 D4                  D3            D2      D1      D0

  Name      SYS_INIT_MASK LOL_B_MASK LOL_A_MASK                               LOS_-                LOS_
                                                                           CLKIN_MASK           XTAL_MASK

  Type              R/W                   R/W                 R/W                R/W                 R/W           R/W     R/W     R/W

Reset value = 0000 0000

  Bit           Name                                                           Function

   7     SYS_INIT_MASK System Initialization Status Mask.
                                 Use this mask bit to prevent the INTR pin (Si5351C only) from going low when SYS-
                                 _INIT is asserted.
                                 0: Do not mask the SYS_INIT interrupt.
                                 1: Mask the SYS_INIT interrupt.

   6       LOL_B_MASK            PLLB Loss Of Lock Status Mask.
                                 Use this mask bit to prevent the INTR pin (Si5351C only) from going low when LOL_B
                                 is asserted.
                                 0: Do not mask the LOL_B interrupt.
                                 1: Mask the LOL_B interrupt.

   5       LOL_A_MASK            PLL A Loss Of Lock Status Mask.
                                 Use this mask bit to prevent the INTR pin (Si5351C only) from going low when LOL_A
                                 is asserted.
                                 0: Do not mask the LOL_A interrupt.
                                 1: Mask the LOL_A interrupt.

   4          LOS_-              CLKIN Loss Of Signal Mask (Si5351C Only).
           CLKIN_MASK            Use this mask bit to prevent the INTR pin (Si5351C only) from going low when LOS_-
                                 CLKIN is asserted.
                                 0: Do not mask the LOS_CLKIN interrupt.
                                 1: Mask the LOS_CLKIN interrupt.

   3           LOS_              Crystal Loss of Signal Mask
            XTAL_MASK            Use this mask bit to prevent the INTR pin (Si5351C only) from going low when
                                 LOS_XTAL is asserted.
                                 0: Do not mask the LOS_XTAL interrupt
                                 1: Mask the LOS_XTAL interrupt

  2:0         Reserved           Leave as default.




16        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619

Register 3. Output Enable Control


   Bit           D7             D6              D5              D4              D3              D2             D1              D0

 Name      CLK7_OEB CLK6_OEB CLK5_OEB CLK4_OEB CLK3_OEB CLK2_OEB CLK1_OEB CLK0_OEB

  Type          R/W            R/W             R/W             R/W             R/W            R/W             R/W             R/W

Reset value = 0000 0000

 Bit       Name                                                           Function

 7:0     CLKx_OEB Output Disable for CLKx.
                        Where x = 0, 1, 2, 3, 4, 5, 6, 7
                        0: Enable CLKx output.
                        1: Disable CLKx output.



Register 9. OEB Pin Enable Control Mask


   Bit           D7             D6              D5              D4              D3              D2             D1              D0

 Name       OEB_MAS OEB_MAS OEB_MAS OEB_MAS OEB_MAS OEB_MAS OEB_MAS OEB_MAS
               K7      K6      K5      K4      K3      K2      K1      K0

  Type          R/W            R/W             R/W             R/W             R/W            R/W             R/W             R/W

Reset value = 0000 0000

 Bit       Name                                                           Function

 7:0     OEB_CLKx OEB pin enable control of CLKx.
                        Where x = 0, 1, 2, 3, 4, 5, 6, 7
                        0: OEB pin controls enable/disable state of CLKx output.
                        1: OEB pin does not control enable/disable state of CLKx output.




         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com            17
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619

Register 15. PLL Input Source


    Bit           D7             D6              D5              D4              D3              D2             D1              D0

  Name           CLKIN_DIV[1:0]                                            PLLB_SRC PLLA_SRC

   Type         R/W             R/W             R/W             R/W             R/W            R/W             R/W             R/W

Reset value = 0000 0000

 Bit            Name                                                            Function

 7:6      CLKIN_DIV[1:0]         ClKIN Input Divider.
                                 Valid PLL input range is 10-40 MHz. If CLKIN is > 40 MHz, CLKIN input divider,
                                 CLKIN_DIV, must be used to bring the PLL input within the 10-40 MHz range.
                                 00b: Divide by 1.
                                 01b: Divide by 2.
                                 10b: Divide by 4.
                                 11b: Divide by 8.

 5:4          Reserved           Leave as default.

  3          PLLB_SRC            Input Source Select for PLLB.
                                 0: Select the XTAL input as the reference clock for PLLB.
                                 1: Select the CLKIN input as the reference clock for PLLB (Si5351C only).

  2          PLLA_SRC            Input Source Select for PLLA.
                                 0: Select the XTAL input as the reference clock for PLLA.
                                 1: Select the CLKIN input as the reference clock for PLLA (Si5351C only).

 1:0          Reserved           Leave as default.




18        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619

Register 16. CLK0 Control


   Bit           D7             D6              D5              D4              D3              D2             D1              D0

 Name      CLK0_PDN         MS0_INT        MS0_SRC         CLK0_INV            CLK0_SRC[1:0]                   CLK0_IDRV[1:0]

  Type          R/W            R/W             R/W             R/W                     R/W                            R/W

Reset value = 0000 0000

 Bit           Name                                                          Function

  7        CLK0_PDN           Clock 0 Power Down.
                              This bit allows powering down the CLK0 output driver to conserve power when the out-
                              put is unused.
                              0: CLK0 is powered up.
                              1: CLK0 is powered down.

  6          MS0_INT          MultiSynth 0 Integer Mode.
                              This bit can be used to force MS0 into Integer mode to improve jitter performance. Note
                              that the fractional mode is necessary when a delay offset is specified for CLK0.
                              0: MS0 operates in fractional division mode.
                              1: MS0 operates in integer mode.

  5         MS0_SRC           MultiSynth Source Select for CLK0.
                              0: Select PLLA as the source for MultiSynth0.
                              1: Select PLLB (Si5351A/C only) or VCXO (Si5351B only) for MultiSynth0.

  4         CLK0_INV          Output Clock 0 Invert.
                              0: Output Clock 0 is not inverted.
                              1: Output Clock 0 is inverted.

 3:2     CLK0_SRC[1:0] Output Clock 0 Input Source.
                              These bits determine the input source for CLK0.
                              00: Select the XTAL as the clock source for CLK0. This option by-passes both synthesis
                              stages (PLL/VCXO & MultiSynth) and connects CLK0 directly to the oscillator which
                              generates an output frequency determined by the XTAL frequency.
                              01: Select CLKIN as the clock source for CLK0. This by-passes both synthesis stages
                              (PLL/VCXO & MultiSynth) and connects CLK0 directly to the CLKIN input. This essen-
                              tially creates a buffered output of the CLKIN input.
                              10: Reserved. Do not select this option.
                              11: Select MultiSynth 0 as the source for CLK0. Select this option when using the
                              Si5351 to generate free-running or synchronous clocks.

 1:0     CLK0_IDRV[1:0] CLK0 Output Rise and Fall time / Drive Strength Control.
                              00: 2 mA
                              01: 4 mA
                              10: 6 mA
                              11: 8 mA




         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com            19
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619

Register 17. CLK1 Control


    Bit           D7             D6              D5              D4              D3              D2             D1              D0

  Name      CLK1_PDN         MS1_INT        MS1_SRC         CLK1_INV            CLK1_SRC[1:0]                   CLK1_IDRV[1:0]

   Type         R/W             R/W             R/W             R/W                     R/W                            R/W

Reset value = 0000 0000

  Bit          Name                                                           Function

   7        CLK1_PDN           Clock 1 Power Down.
                               This bit allows powering down the CLK1 output driver to conserve power when the out-
                               put is unused.
                               0: CLK1 is powered up.
                               1: CLK1 is powered down.

   6         MS1_INT           MultiSynth 1 Integer Mode.
                               When the MS1 divider is an even integer, this bit can be used to force MS1 into integer
                               mode to improve jitter performance. Not valid for odd integers. Note that the fractional
                               mode is necessary when a delay offset is specified for CLK1.
                               0: MS1 operates in fractional division mode.
                               1: MS1 operates in integer mode.

   5         MS1_SRC           MultiSynth Source Select for CLK1.
                               0: Select PLLA as the source for MultiSynth1.
                               1: Select PLLB (Si5351A/C only) or VCXO (Si5351B only) for MultiSynth1.

   4         CLK1_INV          Output Clock 1 Invert.
                               0: Output Clock 1 is not inverted.
                               1: Output Clock 1 is inverted.

  3:2     CLK1_SRC[1:0] Output Clock 1 Input Source.
                               These bits determine the input source for CLK1.
                               00: Select the XTAL as the clock source for CLK1. This option by-passes both synthesis
                               stages (PLL/VCXO & MultiSynth) and connects CLK1 directly to the oscillator which
                               generates an output frequency determined by the XTAL frequency.
                               01: Select CLKIN as the clock source for CLK1. This by-passes both synthesis stages
                               (PLL/VCXO & MultiSynth) and connects CLK1 directly to the CLKIN input. This essen-
                               tially creates a buffered output of the CLKIN input.
                               10: Select Multisynth 0 as the source for CLK1.
                               11: Select MultiSynth 1 as the source for CLK1. Select this option when using the
                               Si5351 to generate free-running or synchronous clocks.

  1:0     CLK1_IDRV[1:0] CLK1 Output Rise and Fall time / Drive Strength Control.
                               00: 2 mA
                               01: 4 mA
                               10: 6 mA
                               11: 8 mA




20        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619

Register 18. CLK2 Control


   Bit           D7             D6              D5              D4              D3              D2             D1              D0

 Name      CLK2_PDN         MS2_INT        MS2_SRC         CLK2_INV            CLK2_SRC[1:0]                   CLK2_IDRV[1:0]

  Type          R/W            R/W             R/W             R/W                     R/W                            R/W

Reset value = 0000 0000

 Bit          Name                                                           Function

  7        CLK2_PDN           Clock 2 Power Down.
                              This bit allows powering down the CLK2 output driver to conserve power when the out-
                              put is unused.
                              0: CLK2 is powered up.
                              1: CLK2 is powered down.

  6         MS2_INT           MultiSynth 2 Integer Mode.
                              When the MS2 divider is an even integer, this bit can be used to force MS2 into integer
                              mode to improve jitter performance. Not valid for odd integers. Note that the fractional
                              mode is necessary when a delay offset is specified for CLK2.
                              0: MS2 operates in fractional division mode.
                              1: MS2 operates in integer mode.

  5        MS2_SRC            MultiSynth Source Select for CLK2.
                              0: Select PLLA as the source for MultiSynth2.
                              1: Select PLLB (Si5351A/C only) or VCXO (Si5351B only) for MultiSynth2.

  4        CLK2_INV           Output Clock 2 Invert.
                              0: Output Clock 2 is not inverted.
                              1: Output Clock 2 is inverted.

 3:2     CLK2_SRC[1:0] Output Clock 2 Input Source.
                              These bits determine the input source for CLK2.
                              00: Select the XTAL as the clock source for CLK2. This option by-passes both synthesis
                              stages (PLL/VCXO & MultiSynth) and connects CLK2 directly to the oscillator which gen-
                              erates an output frequency determined by the XTAL frequency.
                              01: Select CLKIN as the clock source for CLK2. This by-passes both synthesis stages
                              (PLL/VCXO & MultiSynth) and connects CLK2 directly to the CLKIN input. This essen-
                              tially creates a buffered output of the CLKIN input.
                              10: Select Multisynth 0 as the source for CLK2.
                              11: Select MultiSynth 2 as the source for CLK2. Select this option when using the Si5351
                              to generate free-running or synchronous clocks.

 1:0     CLK2_IDRV[1:0] CLK2 Output Rise and Fall time / Drive Strength Control.
                              00: 2 mA
                              01: 4 mA
                              10: 6 mA
                              11: 8 mA




         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com            21
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619

Register 19. CLK3 Control


    Bit           D7             D6              D5              D4              D3              D2             D1              D0

  Name      CLK3_PDN         MS3_INT        MS3_SRC         CLK3_INV            CLK3_SRC[1:0]                   CLK3_IDRV[1:0]

   Type         R/W             R/W             R/W             R/W                     R/W                            R/W

Reset value = 0000 0000

  Bit           Name                                                           Function

   7         CLK3_PDN           Clock 3 Power Down.
                                This bit allows powering down the CLK3 output driver to conserve power when the out-
                                put is unused.
                                0: CLK3 is powered up.
                                1: CLK3 is powered down.
                                Write this bit to a 1 when programming a Si5351A-B-GT 10-MSOP Device.

   6          MS3_INT           MultiSynth 3 Integer Mode.
                                When the MS3 divider is an even integer, this bit can be used to force MS3 into integer
                                mode to improve jitter performance. Not valid for odd integers. Note that the fractional
                                mode is necessary when a delay offset is specified for CLK3.
                                0: MS3 operates in fractional division mode.
                                1: MS3 operates in integer mode.

   5         MS3_SRC            MultiSynth Source Select for CLK3.
                                0: Select PLLA as the source for MultiSynth3.
                                1: Select PLLB (Si5351A/C only) or VCXO (Si5351B only) for MultiSynth3.

   4         CLK3_INV           Output Clock 3 Invert.
                                0: Output Clock 3 is not inverted.
                                1: Output Clock 3 is inverted.

  3:2     CLK3_SRC[1:0] Output Clock 3 Input Source.
                                These bits determine the input source for CLK3.
                                00: Select the XTAL as the clock source for CLK3. This option by-passes both synthe-
                                sis changes (PCL/VCXO and Multisynth) and connects CLK3 directly to the oscillator
                                which generates an output frequency determined by the XTAL frequency.
                                01: Select CLKIN as the clock source for CLK3. This by-passes both synthesis stages
                                (PLL/VCXO and Multisynth) and connects CLK3 directly to the CLKIN input. This
                                essentially creates a buffered output of the CLKIN input.
                                10: Select Multisynth 0 as the source for CLK3.
                                11: Select Multisynth 3 as the source for CLK3. Select this option when using the
                                Si5351 to generate free-running or synchronous clocks.

  1:0     CLK3_IDRV[1:0] CLK3 Output Rise and Fall time / Drive Strength Control.
                                00: 2 mA
                                01: 4 mA
                                10: 6 mA
                                11: 8 mA



22        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619

Register 20. CLK4 Control


   Bit           D7             D6              D5              D4              D3              D2             D1              D0

 Name      CLK4_PDN         MS4_INT        MS4_SRC         CLK4_INV            CLK4_SRC[1:0]                   CLK4_IDRV[1:0]

  Type          R/W            R/W             R/W             R/W                     R/W                            R/W

Reset value = 0000 0000

  Bit          Name                                                           Function

  7         CLK4_PDN           Clock 4 Power Down.
                               This bit allows powering down the CLK4 output driver to conserve power when the out-
                               put is unused.
                               0: CLK4 is powered up.
                               1: CLK4 is powered down.
                               Write this bit to a 1 when programming a Si5351A-B-GT 10-MSOP Device.

  6          MS4_INT           MultiSynth 4 Integer Mode.
                               When the MS4 divider is an even integer, this bit can be used to force MS4 into integer
                               mode to improve jitter performance. Not valid for odd integers. Note that the fractional
                               mode is necessary when a delay offset is specified for CLK4.
                               0: MS4 operates in fractional division mode.
                               1: MS4 operates in integer mode.

  5          MS4_SRC           MultiSynth Source Select for CLK4.
                               0: Select PLLA as the source for MultiSynth4.
                               1: Select PLLB (Si5351A/C only) or VCXO (Si5351B only) for MultiSynth4.

  4          CLK4_INV          Output Clock 4 Invert.
                               0: Output Clock 4 is not inverted.
                               1: Output Clock 4 is inverted.

 3:2     CLK4_SRC[1:0] Output Clock 4 Input Source.
                               These bits determine the input source for CLK4.
                               00: Select the XTAL as the clock source for CLK4. This option by-passes both synthe-
                               sis stages (PLL/VCXO & MultiSynth) and connects CLK4 directly to the oscillator
                               which generates an output frequency determined by the XTAL frequency.
                               01: Select CLKIN as the clock source for CLK4. This by-passes both synthesis stages
                               (PLL/VCXO & MultiSynth) and connects CLK4 directly to the CLKIN input. This essen-
                               tially creates a buffered output of the CLKIN input.
                               10: Reserved. Do not select this option.
                               11: Select MultiSynth 4 as the source for CLK4. Select this option when using the
                               Si5351 to generate free-running or synchronous clocks.

 1:0     CLK4_IDRV[1:0] CLK4 Output Rise and Fall time / Drive Strength Control.
                               00: 2 mA
                               01: 4 mA
                               10: 6 mA
                               11: 8 mA



         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com            23
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619

Register 21. CLK5 Control


    Bit           D7             D6              D5              D4              D3              D2             D1              D0

  Name      CLK5_PDN         MS5_INT        MS5_SRC         CLK5_INV            CLK5_SRC[1:0]                   CLK5_IDRV[1:0]

   Type         R/W             R/W             R/W             R/W                     R/W                            R/W

Reset value = 0000 0000

  Bit           Name                                                           Function

   7         CLK5_PDN           Clock 5 Power Down.
                                This bit allows powering down the CLK5 output driver to conserve power when the out-
                                put is unused.
                                0: CLK5 is powered up.
                                1: CLK5 is powered down.
                                Write this bit to a 1 when programming a Si5351A-B-GT 10-MSOP Device.

   6          MS5_INT           MultiSynth 5 Integer Mode.
                                When the MS5 divider is an even integer, this bit can be used to force MS5 into integer
                                mode to improve jitter performance. Not valid for odd integers. Note that the fractional
                                mode is necessary when a delay offset is specified for CLK5.
                                0: MS5 operates in fractional division mode.
                                1: MS5 operates in integer mode.

   5          MS5_SRC           MultiSynth Source Select for CLK5.
                                0: Select PLLA as the source for MultiSynth5.
                                1: Select PLLB (Si5351A/C only) or VCXO (Si5351B only) for MultiSynth5.

   4          CLK5_INV          Output Clock 5 Invert.
                                0: Output Clock 5 is not inverted.
                                1: Output Clock 5 is inverted.

  3:2     CLK5_SRC[1:0] Output Clock 5 Input Source.
                                These bits determine the input source for CLK5.
                                00: Select the XTAL as the clock source for CLK5. This option by-passes both synthe-
                                sis stages (PLL/VCXO & MultiSynth) and connects CLK5 directly to the oscillator
                                which generates an output frequency determined by the XTAL frequency.
                                01: Select CLKIN as the clock source for CLK5. This by-passes both synthesis stages
                                (PLL/VCXO & MultiSynth) and connects CLK5 directly to the CLKIN input. This essen-
                                tially creates a buffered output of the CLKIN input.
                                10: Select Multisynth 4 as the source for CLK5.
                                11: Select MultiSynth 5 as the source for CLK5. Select this option when using the
                                Si5351 to generate free-running or synchronous clocks.

  1:0     CLK5_IDRV[1:0] CLK5 Output Rise and Fall time / Drive Strength Control.
                                00: 2 mA
                                01: 4 mA
                                10: 6 mA
                                11: 8 mA



24        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619

Register 22. CLK6 Control


   Bit           D7             D6              D5              D4              D3              D2             D1              D0

 Name      CLK6_PDN         FBA_INT        MS6_SRC         CLK6_INV            CLK6_SRC[1:0]                   CLK6_IDRV[1:0]

  Type          R/W            R/W             R/W             R/W                     R/W                            R/W

Reset value = 0000 0000

  Bit          Name                                                           Function

  7         CLK6_PDN           Clock 7 Power Down.
                               This bit allows powering down the CLK6 output driver to conserve power when the out-
                               put is unused.
                               0: CLK6 is powered up.
                               1: CLK6 is powered down.
                               Write this bit to a 1 when programming a Si5351A-B-GT 10-MSOP Device.

  6          FBA_INT           FBA MultiSynth Integer Mode.
                               This bit can be used to force Feedback A Multisynth into Integer mode to improve jitter
                               performance. Note that the fractional mode is necessary when spread spectrum is
                               specified for any output clocks.
                               0: MSNA operates in fractional division mode.
                               1: MSNA operates in integer mode.

  5          MS6_SRC           MultiSynth Source Select for CLK6.
                               0: Select PLLA as the source for MultiSynth6.
                               1: Select PLLB (Si5351A/C only) or VCXO (Si5351B only) for MultiSynth6.

  4          CLK6_INV          Output Clock 6 Invert.
                               0: Output Clock 6 is not inverted.
                               1: Output Clock 6 is inverted.

 3:2     CLK6_SRC[1:0] Output Clock 6 Input Source.
                               These bits determine the input source for CLK6.
                               00: Select the XTAL as the clock source for CLK6. This option by-passes both synthe-
                               sis stages (PLL/VCXO & MultiSynth) and connects CLK6 directly to the oscillator
                               which generates an output frequency determined by the XTAL frequency.
                               01: Select CLKIN as the clock source for CLK6. This by-passes both synthesis stages
                               (PLL/VCXO & MultiSynth) and connects CLK6 directly to the CLKIN input. This essen-
                               tially creates a buffered output of the CLKIN input.
                               10: Select Multisynth 4 as the source for CLK6.
                               11: Select MultiSynth 6 as the source for CLK6. Select this option when using the
                               Si5351 to generate free-running or synchronous clocks.

 1:0     CLK6_IDRV[1:0] CLK6 Output Rise and Fall time / Drive Strength Control.
                               00: 2 mA
                               01: 4 mA
                               10: 6 mA
                               11: 8 mA



         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com            25
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619

Register 23. CLK7 Control


    Bit           D7             D6              D5              D4              D3              D2             D1              D0

  Name      CLK7_PDN         FBB_INT        MS7_SRC         CLK7_INV            CLK7_SRC[1:0]                   CLK7_IDRV[1:0]

   Type         R/W             R/W             R/W             R/W                     R/W                            R/W

Reset value = 0000 0000

  Bit           Name                                                           Function

   7         CLK7_PDN           Clock 7 Power Down.
                                This bit allows powering down the CLK7 output driver to conserve power when the out-
                                put is unused.
                                0: CLK7 is powered up.
                                1: CLK7 is powered down.
                                Write this bit to a 1 when programming a Si5351A-B-GT 10-MSOP Device.

   6          FBB_INT           FBB MultiSynth Integer Mode.
                                This bit can be used to force Feedback B into Integer mode to improve jitter perfor-
                                mance.
                                0: MSNB operates in fractional division mode.
                                1: MSNB operates in integer mode.

   5          MS7_SRC           MultiSynth Source Select for CLK7.
                                0: Select PLLA as the source for MultiSynth7.
                                1: Select PLLB (Si5351A/C only) or VCXO (Si5351B only) for MultiSynth7.

   4          CLK7_INV          Output Clock 7 Invert.
                                0: Output Clock 7 is not inverted.
                                1: Output Clock 7 is inverted.

  3:2     CLK7_SRC[1:0] Output Clock 7 Input Source.
                                These bits determine the input source for CLK7.
                                00: Select the XTAL as the clock source for CLK7. This option by-passes both synthe-
                                sis stages (PLL/VCXO & MultiSynth) and connects CLK7 directly to the oscillator
                                which generates an output frequency determined by the XTAL frequency.
                                01: Select CLKIN as the clock source for CLK7. This by-passes both synthesis stages
                                (PLL/VCXO & MultiSynth) and connects CLK7 directly to the CLKIN input. This essen-
                                tially creates a buffered output of the CLKIN input.
                                10: Select Multisynth 4 as the source for CLK7.
                                11: Select MultiSynth 7 as the source for CLK7. Select this option when using the
                                Si5351 to generate free-running or synchronous clocks.

  1:0     CLK7_IDRV[1:0] CLK7 Output Rise and Fall time / Drive Strength Control.
                                00: 2 mA
                                01: 4 mA
                                10: 6 mA
                                11: 8 mA




26        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619

Register 24. CLK3–0 Disable State


   Bit           D7             D6              D5              D4              D3              D2             D1              D0

 Name          CLK3_DIS_STATE                 CLK2_DIS_STATE                  CLK1_DIS_STATE                 CLK0_DIS_STATE

  Type                 R/W                             R/W                             R/W                            R/W

Reset value = 0000 0000

  Bit             Name                                                          Function

  7:0     CLKx_DIS_STATE             Clock x Disable State.
                                     Where x = 0, 1, 2, 3. These 2 bits determine the state of the CLKx output when dis-
                                     abled. Individual output clocks can be disabled using register Output Enable Con-
                                     trol located at address 3. Outputs are also disabled using the OEB pin.
                                     00: CLKx is set to a LOW state when disabled.
                                     01: CLKx is set to a HIGH state when disabled.
                                     10: CLKx is set to a HIGH IMPEDANCE state when disabled.
                                     11: CLKx is NEVER DISABLED.


Register 25. CLK7–4 Disable State


   Bit           D7             D6              D5              D4              D3              D2             D1              D0

 Name          CLK7_DIS_STATE                 CLK6_DIS_STATE                  CLK5_DIS_STATE                 CLK4_DIS_STATE

  Type                 R/W                             R/W                             R/W                            R/W

Reset value = 0000 0000

  Bit            Name                                                           Function

 7:0      CLKx_DIS_STATE             Clock x Disable State.
                                     Where x = 4, 5, 6, 7. These 2 bits determine the state of the CLKx output when dis-
                                     abled. Individual output clocks can be disabled using register Output Enable Con-
                                     trol located at address 3. Outputs are also disabled using the OEB pin.
                                     00: CLKx is set to a LOW state when disabled.
                                     01: CLKx is set to a HIGH state when disabled.
                                     10: CLKx is set to a HIGH IMPEDANCE state when disabled.
                                     11: CLKx is NEVER DISABLED.




         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com            27
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619

Register 26. Multisynth NA Parameters


     Bit            D7             D6              D5             D4              D3              D2             D1             D0
   Name                                                           MSNA_P3[15:8]

   Type                                                                  R/W
Reset value = xxxx xxxx

   Bit          Name                                                             Function
   7:0       MSNA_P3[15:8]          Multisynth NA Parameter 3.
                                    This 20-bit number is an encoded representation of the denominator for the frac-
                                    tional part of the PLLA Feedback Multisynth Divider.



Register 27. Multisynth NA Parameters


     Bit            D7             D6              D5             D4              D3              D2             D1             D0

   Name                                                            MSNA_P3[7:0]

    Type                                                                 R/W
Reset value = xxxx xxxx

   Bit           Name                                                            Function
   7:0        MSNA_P3[7:0]          Multisynth NA Parameter 3.
                                    This 20-bit number is an encoded representation of the denominator for the frac-
                                    tional part of the PLLA Feedback Multisynth Divider.



Register 28. Multisynth NA Parameters


     Bit            D7             D6              D5             D4              D3              D2             D1             D0

   Name                                 Unused                                         Reserved                 MSNA_P1[17:16]

    Type                                                                 R/W
Reset value = xxxx xxxx

   Bit             Name                                                          Function
   7:4            Unused            Unused.
   3:2           Reserved           Reserved.
                                    Leave as default, 0.
   1:0      MSNA_P1[17:16]          Multisynth NA Parameter 1.
                                    This 18-bit number is an encoded representation of the integer part of the PLLA
                                    Feedback Multisynth divider.




28        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619

Register 29. Multisynth NA Parameters


    Bit            D7             D6              D5             D4              D3             D2              D1             D0

  Name                                                           MSNA_P1[15:8]

   Type                                                                 R/W
Reset value = xxxx xxxx

  Bit          Name                                                             Function
  7:0       MSNA_P1[15:8]          Multisynth NA Parameter 1.
                                   This 18-bit number is an encoded representation of the integer part of the PLLA
                                   Feedback Multisynth divider.



Register 30. Multisynth NA Parameters


    Bit            D7             D6              D5             D4              D3             D2              D1             D0

  Name                                                            MSNA_P1[7:0]

   Type                                                                 R/W
Reset value = xxxx xxxx

  Bit           Name                                                            Function
  7:0        MSNA_P1[7:0]          Multisynth NA Parameter 1.
                                   This 18-bit number is an encoded representation of the integer part of the PLLA
                                   Feedback Multisynth divider.



Register 31. Multisynth NA Parameters


    Bit            D7             D6              D5             D4              D3             D2              D1             D0

  Name                           MSNA_P3[19:16]                                                MSNA_P2[19:16]

   Type                                                                 R/W
Reset value = xxxx xxxx

  Bit         Name                                                              Function
  7:4      MSNA_P3[19:16]          Multisynth NA Parameter 3.
                                   This 20-bit number is an encoded representation of the denominator for the frac-
                                   tional part of the PLLA Feedback Multisynth divider.
  3:0      MSNA_P2[19:16]          Multisynth NA Parameter 2.
                                   This 20-bit number is an encoded representation of the numerator for the fractional
                                   part of the PLLA Feedback Multisynth divider.




         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com            29
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619

Register 32. Multisynth NA Parameters


     Bit            D7             D6              D5             D4              D3             D2              D1             D0

   Name                                                           MSNA_P2[15:8]

    Type                                                                 R/W
Reset value = xxxx xxxx

   Bit          Name                                                             Function
   7:0       MSNA_P2[15:8]          Multisynth NA Parameter 2.
                                    This 20-bit number is an encoded representation of the numerator for the fractional
                                    part of the PLLA Feedback Multisynth divider.



Register 33. Multisynth NA Parameters


     Bit            D7             D6              D5             D4              D3             D2              D1             D0

   Name                                                            MSNA_P2[7:0]

    Type                                                                 R/W
Reset value = xxxx xxxx

   Bit           Name                                                            Function
   7:0        MSNA_P2[7:0]          Multisynth NA Parameter 2.
                                    This 20-bit number is an encoded representation of the numerator for the fractional
                                    part of the PLLA Feedback Multisynth divider.



Register 34. Multisynth NB Parameters


     Bit            D7             D6              D5             D4              D3             D2              D1             D0

   Name                                                           MSNB_P3[15:8]

    Type                                                                 R/W
Reset value = xxxx xxxx

   Bit          Name                                                             Function
   7:0       MSNB_P3[15:8]          Multisynth NA Parameter 3.
                                    This 20-bit number is an encoded representation of the denominator for the frac-
                                    tional part of the PLLA Feedback Multisynth divider.




30        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619

Register 35. Multisynth NB Parameters


    Bit            D7             D6              D5             D4              D3              D2             D1             D0

  Name                                                            MSNB_P3[7:0]

   Type                                                                 R/W
Reset value = xxxx xxxx

  Bit           Name                                                            Function
  7:0        MSNB_P3[7:0]          Multisynth NB Parameter 3.
                                   This 20-bit number is an encoded representation of the denominator for the frac-
                                   tional part of the PLLB Feedback Multisynth divider.



Register 36. Multisynth NB Parameters


    Bit            D7             D6              D5             D4              D3              D2             D1             D0

  Name                                 Unused                                         Reserved                 MSNB_P1[17:16]

   Type                                                                 R/W
Reset value = xxxx xxxx

  Bit             Name                                                          Function
  7:4                                                               Unused
  3:2           Reserved           Reserved.
                                   Leave as default, 0.
  1:0      MSNB_P1[17:16]          Multisynth NB Parameter 1.
                                   This 18-bit number is an encoded representation of the integer part for the frac-
                                   tional part of the PLLB Feedback Multisynth divider.



Register 37. Multisynth NB Parameters


    Bit            D7             D6              D5             D4              D3              D2             D1             D0

  Name                                                           MSNB_P1[15:8]

   Type                                                                 R/W
Reset value = xxxx xxxx

  Bit          Name                                                   Function
  7:0       MSNB_P1[15:8]          Multisynth NB Parameter 1.
                                   This 18-bit number is an encoded representation of the integer part of the PLLB
                                   Feedback Multisynth divider.




         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com            31
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619

Register 38. Multisynth NB Parameters


     Bit            D7             D6              D5             D4              D3             D2              D1             D0

   Name                                                            MSNB_P1[7:0]

    Type                                                                 R/W
Reset value = xxxx xxxx

   Bit           Name                                                  Function
   7:0        MSNB_P1[7:0]          Multisynth NB Parameter 1.
                                    This 18-bit number is an encoded representation of the integer part of the PLLB
                                    Feedback Multisynth divider.



Register 39. Multisynth NB Parameters


     Bit            D7             D6              D5             D4              D3             D2              D1             D0

   Name                           MSNB_P3[19:16]                                                MSNB_P2[19:16]

    Type                                                                 R/W
Reset value = xxxx xxxx

   Bit         Name                                                              Function
   7:4      MSNB_P3[19:16]          Multisynth NB Parameter 3.
                                    This 20-bit number is an encoded representation of the denominator for the frac-
                                    tional part of the PLLB Feedback Multisynth divider.
   3:0      MSNB_P2[19:16]          Multisynth NB Parameter 2.
                                    This 20-bit number is an encoded representation of the numerator for the fractional
                                    part of the PLLB Feedback Multisynth divider.



Register 40. Multisynth NB Parameters


     Bit            D7             D6              D5             D4              D3             D2              D1             D0

   Name                                                           MSNB_P2[15:8]

    Type                                                                 R/W

Reset value = xxxx xxxx

   Bit          Name                                                             Function
   7:0       MSNB_P2[15:8]          Multisynth NB Parameter 2.
                                    This 20-bit number is an encoded representation of the numerator for the fractional
                                    part of the PLLB Feedback Multisynth divider.




32        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619

Register 41. Multisynth NB Parameters


    Bit            D7             D6              D5             D4              D3             D2              D1             D0

  Name                                                            MSNB_P2[7:0]

   Type                                                                 R/W

  Bit           Name                                                   Function
  7:0        MSNB_P2[7:0]          Multisynth NB Parameter 2.
                                   This 20-bit number is an encoded representation of the numerator for the fractional
                                   part of the PLLB Feedback Multisynth divider.



Register 42. Multisynth0 Parameters


    Bit            D7             D6              D5             D4              D3             D2              D1             D0
  Name                                                            MS0_P3[15:8]

   Type                                                                 R/W
Reset value = xxxx xxxx

  Bit           Name                                                            Function
  7:0        MS0_P3[15:8]          Multisynth0 Parameter 3.
                                   This 20-bit number is an encoded representation of the denominator for the frac-
                                   tional part of the MultiSynth0 Divider.



Register 43. Multisynth0 Parameters


    Bit            D7             D6              D5             D4              D3             D2              D1             D0

  Name                                                             MS0_P3[7:0]

   Type                                                                 R/W
Reset value = xxxx xxxx

  Bit              Name                                                          Function
  7:0          MS0_P3[7:0]           Multisynth0 Parameter 3.
                                     This 20-bit number is an encoded representation of the denominator for the frac-
                                     tional part of the MultiSynth0 Divider.




         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com            33
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619

Register 44. Multisynth0 Parameters


     Bit            D7             D6              D5             D4              D3             D2              D1             D0
   Name                                      R0_DIV[2:0]                        MS0_DIVBY4[1:0]                  MS0_P1[17:16]
   Type            R/W                            R/W                            R/W            R/W                    R/W
Reset value = xxxx xxxx

   Bit             Name                                                          Function
    7             Unused
   6:4         R0_DIV[2:0]          R0 Output Divider.
                                    000b: Divide by 1
                                    001b: Divide by 2
                                    010b: Divide by 4
                                    011b: Divide by 8
                                    100b: Divide by 16
                                    101b: Divide by 32
                                    110b: Divide by 64
                                    111b: Divide by 128
   3:2     MS0_DIVBY4[1:0] MS0 Divide by 4 Enable.
                           11: Divide by 4 enabled.
                           00: Divide by a value other than 4.
   1:0       MS0_P1[17:16]          Multisynth0 Parameter 1.
                                    This 18-bit number is an encoded representation of the integer part of the Multi-
                                    Synth0 divider.



Register 45. Multisynth0 Parameters


     Bit            D7             D6              D5             D4              D3             D2             D1              D0
   Name                                                            MS0_P1[15:8]
  Type                                                                   R/W
Reset value = xxxx xxxx


   Bit             Name                                                          Function
   7:0        MS0_P1[15:8]          Multisynth0 Parameter 1.
                                    This 18-bit number is an encoded representation of the integer part of the Multi-
                                    Synth1 divider.




34        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619

Register 46. Multisynth0 Parameters


    Bit            D7             D6              D5             D4              D3             D2              D1             D0

  Name                                                             MS0_P1[7:0]

   Type                                                                 R/W
Reset value = xxxx xxxx

  Bit             Name                                                          Function
  7:0         MS0_P1[7:0]          Multisynth0 Parameter 1.
                                   This 18-bit number is an encoded representation of the integer part of the Multi-
                                   Synth1 divider.



Register 47. Multisynth0 Parameters


    Bit            D7             D6              D5             D4              D3             D2              D1             D0

  Name                            MS0_P3[19:16]                                                 MS0_P2[19:16]

   Type                                  R/W                                                           R/W
Reset value = xxxx xxxx

  Bit             Name                                                          Function
  7:4       MS0_P3[19:16]          Multisynth0 Parameter 3.
                                   This 20-bit number is an encoded representation of the denominator for the frac-
                                   tional part of the MultiSynth0 Divider
  3:0       MS0_P2[19:16]          Multisynth0 Parameter 2.
                                   This 20-bit number is an encoded representation of the numerator for the fractional
                                   part of the MultiSynth1 Divider.



Register 48. Multisynth0 Parameters


    Bit            D7             D6              D5             D4              D3             D2              D1             D0

  Name                                                            MS0_P2[15:8]

   Type                                                                 R/W
Reset value = xxxx xxxx

  Bit             Name                                                          Function
  7:0        MS0_P2[15:8]          Multisynth0 Parameter 2.
                                   This 20-bit number is an encoded representation of the numerator for the fractional
                                   part of the MultiSynth1 Divider.




         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com            35
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619

Register 49. Multisynth0 Parameters


     Bit            D7             D6              D5             D4              D3             D2              D1             D0

   Name                                                             MS0_P2[7:0]

    Type                                                                 R/W
Reset value = xxxx xxxx

   Bit             Name                                                          Function
   7:0         MS0_P2[7:0]          Multisynth0 Parameter 2.
                                    This 20-bit number is an encoded representation of the numerator for the fractional
                                    part of the MultiSynth1 Divider.



Register 50. Multisynth1 Parameters


     Bit            D7             D6              D5             D4              D3             D2              D1             D0

   Name                                                            MS1_P3[15:8]

    Type                                                                 R/W
Reset value = xxxx xxxx

   Bit             Name                                                          Function
   7:0        MS1_P3[15:8]          Multisynth1 Parameter 3.
                                    This 20-bit number is an encoded representation of the denominator for the frac-
                                    tional part of the MultiSynth1 Divider.



Register 51. Multisynth1 Parameters


     Bit            D7             D6              D5             D4              D3             D2              D1             D0

   Name                                                             MS1_P3[7:0]

    Type                                                                 R/W
Reset value = xxxx xxxx

   Bit             Name                                                          Function
   7:0         MS1_P3[7:0]          Multisynth1 Parameter 3.
                                    This 20-bit number is an encoded representation of the denominator for the frac-
                                    tional part of the MultiSynth1 Divider.




36        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619

Register 52. Multisynth1 Parameters


    Bit            D7             D6              D5             D4              D3             D2              D1             D0
  Name                                      R1_DIV[2:0]                        MS1_DIVBY4[1:0]                  MS1_P1[17:16]

   Type           R/W                            R/W                            R/W            R/W                    R/W
Reset value = xxxx xxxx

  Bit             Name                                                          Function
   7             Unused
  6:4         R1_DIV[2:0]          R1 Output Divider.
                                   000b: Divide by 1
                                   001b: Divide by 2
                                   010b: Divide by 4
                                   011b: Divide by 8
                                   100b: Divide by 16
                                   101b: Divide by 32
                                   110b: Divide by 64
                                   111b: Divide by 128
  3:2     MS1_DIVBY4[1:0] MS1 Divide by 4 Enable.
                          11: Divide by 4 enabled.
                          00: Divide by a value other than 4.
  1:0       MS1_P1[17:16]          Multisynth1 Parameter 1.
                                   This 18-bit number is an encoded representation of the integer part of the Multi-
                                   Synth1 divider.



Register 53. Multisynth1 Parameters


    Bit            D7             D6              D5             D4              D3             D2              D1             D0

  Name                                                            MS1_P1[15:8]

   Type                                                                 R/W
Reset value = xxxx xxxx

  Bit             Name                                                          Function
  7:0        MS1_P1[15:8]          Multisynth1 Parameter 1.
                                   This 18-bit number is an encoded representation of the integer part of the Multi-
                                   Synth1 divider.




         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com            37
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619

Register 54. Multisynth1 Parameters


     Bit            D7             D6              D5             D4              D3             D2              D1             D0

   Name                                                             MS1_P1[7:0]

    Type                                                                 R/W
Reset value = xxxx xxxx

   Bit             Name                                                          Function
   7:0         MS1_P1[7:0]          Multisynth1 Parameter 1.
                                    This 18-bit number is an encoded representation of the integer part of the Multi-
                                    Synth1 divider.



Register 55. Multisynth1 Parameters


     Bit             D7             D6             D5              D4             D3             D2              D1             D0

   Name                             MS1_P3[19:16]                                                MS1_P2[19:16]

    Type                                   R/W                                                          R/W
Reset value = xxxx xxxx

   Bit             Name                                                          Function
   7:4       MS1_P3[19:16]          Multisynth1 Parameter 3.
                                    This 20-bit number is an encoded representation of the denominator for the frac-
                                    tional part of the Multisynth1 Divider
   3:0       MS1_P2[19:16]          Multisynth1 Parameter 2.
                                    This 20-bit number is an encoded representation of the numerator for the fractional
                                    part of the MultiSynth1 Divider.



Register 56. Multisynth1 Parameters


     Bit            D7             D6              D5             D4              D3             D2              D1             D0

   Name                                                            MS1_P2[15:8]

    Type                                                                 R/W
Reset value = xxxx xxxx

   Bit             Name                                                          Function
   7:0        MS1_P2[15:8]          Multisynth1 Parameter 2.
                                    This 20-bit number is an encoded representation of the numerator for the fractional
                                    part of the MultiSynth1 divider.




38        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619

Register 57. Multisynth1 Parameters


    Bit            D7             D6              D5             D4              D3             D2              D1             D0

  Name                                                             MS1_P2[7:0]

   Type                                                                 R/W
Reset value = xxxx xxxx

  Bit             Name                                                          Function
  7:0         MS1_P2[7:0]          Multisynth1 Parameter 2.
                                   This 20-bit number is an encoded representation of the numerator for the fractional
                                   part of the MultiSynth1 divider.



Register 58. Multisynth2 Parameters


    Bit            D7             D6              D5             D4              D3             D2              D1             D0

  Name                                                            MS2_P3[15:8]

   Type                                                                 R/W
Reset value = xxxx xxxx

  Bit             Name                                                          Function
  7:0        MS2_P3[15:8]          Multisynth2 Parameter 3.
                                   This 20-bit number is an encoded representation of the denominator for the frac-
                                   tional part of the MultiSynth2 divider.



Register 59. Multisynth2 Parameters


    Bit            D7             D6              D5             D4              D3             D2              D1             D0

  Name                                                             MS2_P3[7:0]

   Type                                                                 R/W
Reset value = xxxx xxxx

  Bit             Name                                                          Function
  7:0         MS2_P3[7:0]          Multisynth2 Parameter 3.
                                   This 20-bit number is an encoded representation of the denominator for the frac-
                                   tional part of the MultiSynth2 divider.




         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com            39
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619

Register 60. Multisynth2 Parameters


     Bit            D7             D6              D5             D4              D3             D2             D1              D0

   Name                                      R2_DIV[2:0]                        MS2_DIVBY4[1:0]                 MS2_P1[17:16]

    Type           R/W                            R/W                            R/W            R/W                    R/W
Reset value = xxxx xxxx

   Bit             Name                                                          Function
    7             Unused
   6:4         R2_DIV[2:0]          R2 Output Divider.
                                    000b: Divide by 1
                                    001b: Divide by 2
                                    010b: Divide by 4
                                    011b: Divide by 8
                                    100b: Divide by 16
                                    101b: Divide by 32
                                    110b: Divide by 64
                                    111b: Divide by 128
   3:2     MS2_DIVBY4[1:0] MS2 Divide by 4 Enable.
                           11: Divide by 4 enabled.
                           00: Divide by a value other than 4.
   1:0       MS2_P1[17:16]          Multisynth2 Parameter 1.
                                    This 18-bit number is an encoded representation of the integer part of the Multi-
                                    synth2 divider.



Register 61. Multisynth2 Parameters


     Bit            D7             D6              D5             D4              D3             D2              D1             D0

   Name                                                            MS2_P1[15:8]

    Type                                                                 R/W
Reset value = xxxx xxxx

   Bit             Name                                                          Function
   7:0        MS2_P1[15:8]          Multisynth2 Parameter 1.
                                    This 18-bit number is an encoded representation of the integer part of the Multi-
                                    synth2 divider.




40        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619

Register 62. Multisynth2 Parameters


    Bit            D7             D6              D5             D4              D3             D2              D1             D0

  Name                                                             MS2_P1[7:0]

   Type                                                                 R/W
Reset value = xxxx xxxx

  Bit             Name                                                          Function
  7:0         MS2_P1[7:0]          Multisynth2 Parameter 1.
                                   This 18-bit number is an encoded representation of the integer part of the Multi-
                                   synth2 divider.



Register 63. Multisynth2 Parameters


    Bit             D7             D6             D5              D4             D3             D2              D1             D0

   Name                            MS2_P3[19:16]                                                MS2_P2[19:16]

   Type                                   R/W                                                          R/W
Reset value = xxxx xxxx

  Bit             Name                                                          Function
  7:4       MS2_P3[19:16]          Multisynth2 Parameter 3.
                                   This 20-bit number is an encoded representation of the denominator for the frac-
                                   tional part of the Multisynth2 divider
  3:0       MS2_P2[19:16]          Multisynth2 Parameter 2.
                                   This 20-bit number is an encoded representation of the numerator for the fractional
                                   part of the MultiSynth2 divider.



Register 64. Multisynth2 Parameters


    Bit            D7             D6              D5             D4              D3             D2              D1             D0

  Name                                                            MS2_P2[15:8]

   Type                                                                 R/W
Reset value = xxxx xxxx

  Bit             Name                                                          Function
  7:0        MS2_P2[15:8]          Multisynth2 Parameter 2.
                                   This 20-bit number is an encoded representation of the numerator for the fractional
                                   part of the Multisynth2 divider.



         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com            41
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619

Register 65. Multisynth2 Parameters


     Bit            D7             D6              D5             D4              D3             D2              D1             D0

   Name                                                             MS2_P2[7:0]

    Type                                                                 R/W
Reset value = xxxx xxxx

   Bit             Name                                                          Function
   7:0         MS2_P2[7:0]          Multisynth2 Parameter 2.
                                    This 20-bit number is an encoded representation of the numerator for the fractional
                                    part of the Multisynth2 divider.



Register 66. Multisynth3 Parameters


     Bit            D7             D6              D5             D4              D3             D2              D1             D0

   Name                                                            MS3_P3[15:8]

    Type                                                                 R/W
Reset value = xxxx xxxx

   Bit             Name                                                          Function
   7:0        MS3_P3[15:8]          Multisynth3 Parameter 3.
                                    This 20-bit number is an encoded representation of the denominator for the frac-
                                    tional part of the Multisynth3 divider.



Register 67. Multisynth3 Parameters


     Bit            D7             D6              D5             D4              D3             D2              D1             D0

   Name                                                             MS3_P3[7:0]

    Type                                                                 R/W
Reset value = xxxx xxxx

   Bit             Name                                                          Function
   7:0         MS3_P3[7:0]          Multisynth3 Parameter 3.
                                    This 20-bit number is an encoded representation of the denominator for the frac-
                                    tional part of the Multisynth3 divider.




42        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619

Register 68. Multisynth3 Parameters


    Bit            D7             D6              D5             D4              D3             D2             D1              D0

  Name                                      R3_DIV[2:0]                        MS3_DIVBY4[1:0]                 MS3_P1[17:16]

   Type           R/W                            R/W                            R/W            R/W                    R/W
Reset value = xxxx xxxx

  Bit             Name                                                          Function
   7             Unused
  6:4         R3_DIV[2:0]          R3 Output Divider.
                                   000b: Divide by 1
                                   001b: Divide by 2
                                   010b: Divide by 4
                                   011b: Divide by 8
                                   100b: Divide by 16
                                   101b: Divide by 32
                                   110b: Divide by 64
                                   111b: Divide by 128
  3:2     MS3_DIVBY4[1:0] MS3 Divide by 4 Enable.
                          11: Divide by 4 enabled.
                          00: Divide by a value other than 4.
  1:0       MS3_P1[17:16]          Multisynth3 Parameter 1.
                                   This 18-bit number is an encoded representation of the integer part of the Multi-
                                   synth3 divider.



Register 69. Multisynth3 Parameters


    Bit            D7             D6              D5             D4              D3             D2              D1             D0

  Name                                                            MS3_P1[15:8]

   Type                                                                 R/W
Reset value = xxxx xxxx

  Bit             Name                                                          Function
  7:0        MS3_P1[15:8]          Multisynth3 Parameter 1.
                                   This 18-bit number is an encoded representation of the integer part of the Multi-
                                   synth3 divider.




         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com            43
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619

Register 70. Multisynth3 Parameters


     Bit            D7             D6              D5             D4              D3             D2              D1             D0

   Name                                                             MS3_P1[7:0]

    Type                                                                 R/W
Reset value = xxxx xxxx

   Bit             Name                                                          Function
   7:0         MS3_P1[7:0]          Multisynth3 Parameter 1.
                                    This 18-bit number is an encoded representation of the integer part of the Multi-
                                    synth3 divider.



Register 71. Multisynth3 Parameters


     Bit             D7             D6             D5              D4             D3             D2              D1             D0

   Name                             MS3_P3[19:16]                                                MS3_P2[19:16]

    Type                                   R/W                                                          R/W
Reset value = xxxx xxxx

   Bit             Name                                                          Function
   7:4       MS3_P3[19:16]          Multisynth3 Parameter 3.
                                    This 20-bit number is an encoded representation of the denominator for the frac-
                                    tional part of the Multisynth3 divider
   3:0       MS3_P2[19:16]          Multisynth3 Parameter 2.
                                    This 20-bit number is an encoded representation of the numerator for the fractional
                                    part of the MultiSynth3 divider.



Register 72. Multisynth3 Parameters


     Bit            D7             D6              D5             D4              D3             D2              D1             D0

   Name                                                            MS3_P2[15:8]

    Type                                                                 R/W
Reset value = xxxx xxxx

   Bit             Name                                                          Function
   7:0        MS3_P2[15:8]          Multisynth3 Parameter 2.
                                    This 20-bit number is an encoded representation of the numerator for the fractional
                                    part of the Multisynth3 divider.



44        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619

Register 73. Multisynth3 Parameters


    Bit            D7             D6              D5             D4              D3             D2              D1             D0

  Name                                                             MS3_P2[7:0]

   Type                                                                 R/W
Reset value = xxxx xxxx

  Bit             Name                                                          Function
  7:0         MS3_P2[7:0]          Multisynth3 Parameter 2.
                                   This 20-bit number is an encoded representation of the numerator for the fractional
                                   part of the Multisynth3 divider.



Register 74. Multisynth4 Parameters


    Bit            D7             D6              D5             D4              D3             D2              D1             D0

  Name                                                            MS4_P3[15:8]

   Type                                                                 R/W
Reset value = xxxx xxxx

  Bit             Name                                                          Function
  7:0        MS4_P3[15:8]          Multisynth4 Parameter 3.
                                   This 20-bit number is an encoded representation of the denominator for the frac-
                                   tional part of the Multisynth4 divider.



Register 75. Multisynth4 Parameters


    Bit            D7             D6              D5             D4              D3             D2              D1             D0

  Name                                                             MS4_P3[7:0]

   Type                                                                 R/W
Reset value = xxxx xxxx

  Bit             Name                                                          Function
  7:0         MS4_P3[7:0]          Multisynth4 Parameter 3.
                                   This 20-bit number is an encoded representation of the numerator for the fractional
                                   part of the Multisynth4 divider.




         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com            45
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619

Register 76. Multisynth4 Parameters


     Bit            D7             D6              D5             D4              D3             D2             D1              D0

   Name                                      R4_DIV[2:0]                        MS4_DIVBY4[1:0]                 MS4_P1[17:16]

    Type           R/W                            R/W                            R/W            R/W                    R/W
Reset value = xxxx xxxx

   Bit             Name                                                          Function
    7             Unused
   6:4         R4_DIV[2:0]          R4 Output Divider.
                                    000b: Divide by 1
                                    001b: Divide by 2
                                    010b: Divide by 4
                                    011b: Divide by 8
                                    100b: Divide by 16
                                    101b: Divide by 32
                                    110b: Divide by 64
                                    111b: Divide by 128
   3:2     MS4_DIVBY4[1:0] MS4 Divide by 4 Enable.
                           11: Divide by 4 enabled.
                           00: Divide by a value other than 4.
   1:0       MS4_P1[17:16]          Multisynth4 Parameter 1.
                                    This 18-bit number is an encoded representation of the integer part of the Multi-
                                    synth4 divider.



Register 77. Multisynth4 Parameters


     Bit            D7             D6              D5             D4              D3             D2              D1             D0

   Name                                                            MS4_P1[15:8]

    Type                                                                 R/W
Reset value = xxxx xxxx

   Bit             Name                                                          Function
   7:0        MS4_P1[15:8]          Multisynth4 Parameter 1.
                                    This 18-bit number is an encoded representation of the integer part of the Multi-
                                    synth4 divider.




46        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619

Register 78. Multisynth4 Parameters


    Bit            D7             D6              D5             D4              D3             D2              D1             D0

  Name                                                             MS4_P1[7:0]

   Type                                                                 R/W
Reset value = xxxx xxxx

  Bit             Name                                                          Function
  7:0         MS4_P1[7:0]          Multisynth4 Parameter 1.
                                   This 18-bit number is an encoded representation of the integer part of the Multi-
                                   synth4 divider.



Register 79. Multisynth4 Parameters


    Bit             D7             D6             D5              D4             D3             D2              D1             D0

   Name                            MS4_P3[19:16]                                                MS4_P2[19:16]

   Type                                   R/W                                                          R/W
Reset value = xxxx xxxx

  Bit             Name                                                          Function
  7:4       MS4_P3[19:16]          Multisynth4 Parameter 3.
                                   This 20-bit number is an encoded representation of the denominator for the frac-
                                   tional part of the Multisynth4 divider
  3:0       MS4_P2[19:16]          Multisynth4 Parameter 2.
                                   This 20-bit number is an encoded representation of the numerator for the fractional
                                   part of the MultiSynth4 divider.



Register 80. Multisynth4 Parameters


    Bit            D7             D6              D5             D4              D3             D2              D1             D0

  Name                                                            MS4_P2[15:8]

   Type                                                                 R/W
Reset value = xxxx xxxx

  Bit             Name                                                          Function
  7:0        MS4_P2[15:8]          Multisynth4 Parameter 2.
                                   This 20-bit number is an encoded representation of the numerator for the fractional
                                   part of the Multisynth4 Divider.



         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com            47
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619

Register 81. Multisynth4 Parameters


     Bit            D7             D6              D5             D4              D3             D2              D1             D0

   Name                                                             MS4_P2[7:0]

    Type                                                                 R/W
Reset value = xxxx xxxx

   Bit             Name                                                          Function
   7:0         MS4_P2[7:0]          Multisynth4 Parameter 2.
                                    This 20-bit number is an encoded representation of the numerator for the fractional
                                    part of the Multisynth4 divider.



Register 82. Multisynth5 Parameters


     Bit            D7             D6              D5             D4              D3             D2              D1             D0

   Name                                                            MS5_P3[15:8]

    Type                                                                 R/W
Reset value = xxxx xxxx

   Bit             Name                                                          Function
   7:0        MS5_P3[15:8]          Multisynth5 Parameter 3.
                                    This 20-bit number is an encoded representation of the denominator for the frac-
                                    tional part of the Multisynth5 divider.



Register 83. Multisynth5 Parameters


     Bit            D7             D6              D5             D4              D3             D2              D1             D0

   Name                                                             MS5_P3[7:0]

    Type                                                                 R/W
Reset value = xxxx xxxx

   Bit             Name                                                          Function
   7:0         MS5_P3[7:0]          Multisynth5 Parameter 3.
                                    This 20-bit number is an encoded representation of the denominator for the frac-
                                    tional part of the Multisynth5 divider.




48        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619

Register 84. Multisynth5 Parameters


    Bit            D7             D6              D5             D4              D3             D2             D1              D0

  Name                                      R5_DIV[2:0]                        MS5_DIVBY4[1:0]                 MS5_P1[17:16]

   Type           R/W                            R/W                            R/W            R/W                    R/W
Reset value = xxxx xxxx

  Bit             Name                                                          Function
   7             Unused
  6:4         R5_DIV[2:0]          R5 Output Divider.
                                   000b: Divide by 1
                                   001b: Divide by 2
                                   010b: Divide by 4
                                   011b: Divide by 8
                                   100b: Divide by 16
                                   101b: Divide by 32
                                   110b: Divide by 64
                                   111b: Divide by 128
  3:2     MS5_DIVBY4[1:0] MS5 Divide by 4 Enable.
                          11: Divide by 4 enabled.
                          00: Divide by a value other than 4.
  1:0       MS5_P1[17:16]          Multisynth5 Parameter 1.
                                   This 18-bit number is an encoded representation of the integer part of the Multi-
                                   synth5 divider.



Register 85. Multisynth5 Parameters


    Bit            D7             D6              D5             D4              D3             D2              D1             D0

  Name                                                            MS5_P1[15:8]

   Type                                                                 R/W
Reset value = xxxx xxxx

  Bit             Name                                                          Function
  7:0        MS5_P1[15:8]          Multisynth5 Parameter 1.
                                   This 18-bit number is an encoded representation of the integer part of the Multi-
                                   synth5 divider.




         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com            49
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619

Register 86. Multisynth5 Parameters


     Bit            D7             D6              D5             D4              D3             D2              D1             D0

   Name                                                             MS5_P1[7:0]

    Type                                                                 R/W
Reset value = xxxx xxxx

   Bit             Name                                                          Function
   7:0         MS5_P1[7:0]          Multisynth5 Parameter 1.
                                    This 18-bit number is an encoded representation of the integer part of the Multi-
                                    synth5 divider.



Register 87. Multisynth5 Parameters


     Bit             D7             D6             D5              D4             D3             D2              D1             D0

   Name                             MS5_P3[19:16]                                                MS5_P2[19:16]

    Type                                   R/W                                                          R/W
Reset value = xxxx xxxx

   Bit             Name                                                          Function
   7:4       MS5_P3[19:16]          Multisynth5 Parameter 3.
                                    This 20-bit number is an encoded representation of the denominator for the frac-
                                    tional part of the Multisynth5 divider
   3:0       MS5_P2[19:16]          Multisynth5 Parameter 2.
                                    This 20-bit number is an encoded representation of the numerator for the fractional
                                    part of the MultiSynth5 divider.



Register 88. Multisynth5 Parameters


     Bit            D7             D6              D5             D4              D3             D2              D1             D0

   Name                                                            MS5_P2[15:8]

    Type                                                                 R/W
Reset value = xxxx xxxx

   Bit             Name                                                          Function
   7:0        MS5_P2[15:8]          Multisynth5 Parameter 2.
                                    This 20-bit number is an encoded representation of the numerator for the fractional
                                    part of the Multisynth5 Divider.



50        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619

Register 89. Multisynth5 Parameters


    Bit            D7             D6              D5             D4              D3             D2              D1             D0

  Name                                                             MS5_P2[7:0]

   Type                                                                 R/W
Reset value = xxxx xxxx

  Bit             Name                                                          Function
  7:0         MS5_P2[7:0]          Multisynth5 Parameter 2.
                                   This 20-bit number is an encoded representation of the numerator for the fractional
                                   part of the Multisynth5 Divider.



Register 90. Multisynth6 Parameters


    Bit            D7             D6              D5             D4              D3             D2              D1             D0

  Name                                                             MS6_P1[7:0]

   Type                                                                 R/W
Reset value = xxxx xxxx

  Bit             Name                                                          Function
  7:0         MS6_P1[7:0]          Multisynth6 Parameter 1.
                                   This 8-bit number is the Multisynth6 divide ratio. Multisynth6 divide ratio can only be
                                   even integers greater than or equal to 6. All other divide values are invalid.



Register 91. Multisynth7 Parameters


    Bit            D7             D6              D5             D4              D3             D2              D1             D0

  Name                                                             MS7_P1[7:0]

   Type                                                                 R/W
Reset value = xxxx xxxx

  Bit             Name                                                          Function
  7:0         MS7_P1[7:0]          Multisynth7 Parameter 1.
                                   This 8-bit number is the Multisynth6 divide ratio. Multisynth6 divide ratio can only be
                                   even integers greater than or equal to 6. All other divide values are invalid.




         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com            51
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619

Register 92. Clock 6 and 7 Output Divider


     Bit            D7             D6              D5             D4              D3             D2             D1              D0

   Name         Reserved                     R7_DIV[2:0]                     Reserved                      R6_DIV[2:0]

    Type           R/W                            R/W                            R/W                            R/W
Reset value = xxxx xxxx

   Bit             Name                                                          Function
    7            Reserved           Leave as default.
   6:4         R7_DIV[2:0]          R7 Output Divider.
                                    000b: Divide by 1
                                    001b: Divide by 2
                                    010b: Divide by 4
                                    011b: Divide by 8
                                    100b: Divide by 16
                                    101b: Divide by 32
                                    110b: Divide by 64
                                    111b: Divide by 128
    3            Reserved           Leave as default.
   1:0         R6_DIV[2:0]          R6 Output Divider.
                                    000b: Divide by 1
                                    001b: Divide by 2
                                    010b: Divide by 4
                                    011b: Divide by 8
                                    100b: Divide by 16
                                    101b: Divide by 32
                                    110b: Divide by 64
                                    111b: Divide by 128




52        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619

Register 149. Spread Spectrum Parameters


   Bit           D7             D6              D5              D4              D3              D2             D1              D0
 Name        SSC_EN                                                     SSDN_P2[14:8]
  Type                                                                 R/W
Reset value = xxxx xxxx

 Bit            Name                                                           Function
  7           SSC_EN             Spread Spectrum Enable
                                 1: Enable
                                 0: Disable
                                 Note: Spread Spectrum Enable control pin is available on the Si5351A and B devices. Spread
                                       spectrum enable functionality is a logical OR of the SSEN pin and SSC_EN register bit,
                                       so for the SSEN pin to work properly, this register bit must be set to 0.
 6:0      SSDN_P2[14:8]          PLL A Spread Spectrum Down Parameter 2.


Register 150. Spread Spectrum Parameters


   Bit           D7             D6              D5              D4              D3              D2             D1              D0
 Name                                                            SSDN_P2[7:0]
  Type                                                                 R/W
Reset value = xxxx xxxx

 Bit            Name                                                           Function
 7:0       SSDN_P2[7:0]          PLL A Spread Spectrum Down Parameter 2.


Register 151. Spread Spectrum Parameters


  Bit            D7              D6              D5              D4              D3             D2              D1              D0
 Name     SSC_MODE                                                       SSDN_P3[14:8]
 Type                                                                  R/W
Reset value = xxxx xxxx

 Bit            Name                                                           Function
  7         SSC_MODE             Spread Spectrum Mode.
                                 0: Down Spread
                                 1: Center Spread
 6:0      SSDN_P3[14:8]          PLL A Spread Spectrum Down Parameter 3.




         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com            53
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619

Register 152. Spread Spectrum Parameters


   Bit            D7              D6              D5              D4              D3             D2              D1              D0
 Name                                                             SSDN_P3[7:0]
  Type                                                                  R/W
Reset value = xxxx xxxx

  Bit            Name                                                           Function
 7:0        SSDN_P3[7:0]          PLL A Spread Spectrum Down Parameter 3.


Register 153. Spread Spectrum Parameters


   Bit            D7              D6              D5              D4              D3             D2              D1              D0
 Name                                                             SSDN_P1[7:0]
  Type                                                                  R/W
Reset value = xxxx xxxx

  Bit            Name                                                           Function
 7:0        SSDN_P1[7:0]          PLL A Spread Spectrum Down Parameter 1.


Register 154. Spread Spectrum Parameters


   Bit            D7              D6              D5              D4              D3             D2              D1              D0
 Name                              SSUDP[11:8]                                                   SSDN_P1[11:8]
  Type                                                                  R/W
Reset value = xxxx xxxx

  Bit            Name                                                           Function
 7:4        SSUDP[11:8]           PLL A Spread Spectrum Up/Down Parameter.
 3:0       SSDN_P1[11:8]          PLL A Spread Spectrum Down Parameter 1.


Register 155. Spread Spectrum Parameters


   Bit            D7              D6              D5              D4              D3             D2              D1              D0
 Name                                                              SSUDP[7:0]
  Type                                                                  R/W
Reset value = xxxx xxxx

  Bit            Name                                                           Function
 7:0         SSUDP[7:0]           PLL A Spread Spectrum Up/Down Parameter.


54        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619

Register 156. Spread Spectrum Parameters


  Bit            D7              D6              D5              D4              D3             D2              D1              D0
 Name        Unused                                                      SSUP_P2[14:8]
 Type                                                                  R/W
Reset value = xxxx xxxx

 Bit            Name                                                           Function
  7            Unused            Unused.
 6:0      SSUP_P2[14:8]          PLL A Spread Spectrum Up Parameter 2.


Register 157. Spread Spectrum Parameters


  Bit            D7              D6              D5              D4              D3             D2              D1              D0
 Name                                                            SSUP_P2[7:0]
 Type                                                                  R/W
Reset value = xxxx xxxx

 Bit            Name                                                           Function
 7:0       SSUP_P2[7:0]          PLL A Spread Spectrum Up Parameter 2.


Register 158. Spread Spectrum Parameters


  Bit            D7              D6              D5              D4              D3             D2              D1              D0
 Name        Unused                                                      SSUP_P3[14:8]
 Type                                                                  R/W
Reset value = xxxx xxxx

 Bit            Name                                                           Function
  7            Unused            Unused.
 6:0      SSUP_P3[14:8]          PLL A Spread Spectrum Up Parameter 3.




         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com            55
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619

Register 159. Spread Spectrum Parameters


   Bit            D7              D6              D5              D4              D3             D2              D1              D0
 Name                                                             SSUP_P3[7:0]
  Type                                                                  R/W
Reset value = xxxx xxxx

  Bit            Name                                                           Function
 7:0        SSUP_P3[7:0]          PLL A Spread Spectrum Up Parameter 3.


Register 160. Spread Spectrum Parameters


   Bit            D7              D6              D5              D4              D3             D2              D1              D0
 Name                                                             SSUP_P1[7:0]
  Type                                                                  R/W
Reset value = xxxx xxxx

  Bit            Name                                                           Function
 7:0        SSUP_P1[7:0]          PLL A Spread Spectrum Up Parameter 1.


Register 161. Spread Spectrum Parameters


   Bit            D7              D6              D5              D4              D3             D2              D1              D0
 Name                             SS_NCLK[3:0]                                                   SSUP_P1[11:8]
  Type                                                                  R/W
Reset value = xxxx xxxx

  Bit            Name                                                           Function
 7:4        SS_NCLK[3:0]          Must write 0000b to these bits.
 3:0       SSUP_P1[11:8]          PLL A Spread Spectrum Up Parameter 1.


Register 162. VCXO Parameter


   Bit            D7              D6              D5              D4              D3             D2              D1              D0
 Name                                                          VCXO_Param[7:0]
  Type                                                                  R/W
Reset value = xxxx xxxx

  Bit            Name                                                           Function
 7:0     VCXO_Param[7:0] VCXO Parameter.


56        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619

Register 163. VCXO Parameter


  Bit            D7              D6              D5              D4              D3             D2              D1              D0
 Name                                                        VCXO_Param[15:8]
 Type                                                                  R/W
Reset value = xxxx xxxx

 Bit            Name                                                           Function
 7:0     VCXO_Param[15:8] VCXO Parameter.


Register 164. VCXO Parameter


  Bit            D7              D6              D5              D4              D3             D2              D1              D0
 Name                 Reserved                                               VCXO_Param[21:16]
  Type                                                                 R/W
Reset value = xxxx xxxx

 Bit             Name                                                           Function
 7:6           Reserved               Reserved. Only write 00b to these bits.
 5:0     VCXO_Param[21:16] VCXO Parameter.


Register 165. CLK0 Initial Phase Offset


   Bit           D7              D6             D5              D4              D3              D2             D1              D0
 Name                                                                 CLK0_PHOFF[6:0]
  Type          R/W            R/W             R/W             R/W             R/W            R/W             R/W             R/W
Reset value = 0000 0000

 Bit            Name                                                           Function
  7           Reserved           Only write 0 to this bit.
 6:0     CLK0_PHOFF[6:0] Clock 0 Initial Phase Offset.
                                 CLK0_PHOFF[6:0] is an unsigned integer with one LSB equivalent to a time delay of
                                 Tvco/4, where Tvco is the period of the VCO/PLL associated with this output.




         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com            57
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619

Register 166. CLK1 Initial Phase Offset


    Bit           D7             D6              D5              D4              D3              D2             D1              D0
  Name                                                                 CLK1_PHOFF[6:0]
   Type         R/W             R/W             R/W             R/W             R/W            R/W             R/W             R/W
Reset value = 0000 0000

  Bit            Name                                                           Function
   7           Reserved           Only write 0 to this bit.
 6:0      CLK1_PHOFF[6:0] Clock 1 Initial Phase Offset.
                                  CLK1_PHOFF[6:0] is an unsigned integer with one LSB equivalent to a time delay of
                                  Tvco/4, where Tvco is the period of the VCO/PLL associated with this output.


Register 167. CLK2 Initial Phase Offset


    Bit           D7             D6              D5              D4              D3              D2             D1              D0
  Name                                                                 CLK2_PHOFF[6:0]
   Type         R/W             R/W             R/W             R/W             R/W            R/W             R/W             R/W
Reset value = 0000 0000

  Bit            Name                                                           Function
   7           Reserved           Only write 0 to this bit.
 6:0      CLK2_PHOFF[6:0] Clock 2 Initial Phase Offset.
                                  CLK2_PHOFF[6:0] is an unsigned integer with one LSB equivalent to a time delay of
                                  Tvco/4, where Tvco is the period of the VCO/PLL associated with this output.


Register 168. CLK3 Initial Phase Offset


    Bit           D7             D6              D5              D4              D3              D2             D1              D0
  Name                                                                 CLK3_PHOFF[6:0]
   Type         R/W             R/W             R/W             R/W             R/W            R/W             R/W             R/W
Reset value = 0000 0000

  Bit            Name                                                           Function
   7           Reserved           Only write 0 to this bit.
  6:0     CLK3_PHOFF[6:0] Clock 3 Initial Phase Offset.
                                  CLK3_PHOFF[6:0] is an unsigned integer with one LSB equivalent to a time delay of
                                  Tvco/4, where Tvco is the period of the VCO/PLL associated with this output.




58        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619

Register 169. CLK4 Initial Phase Offset


   Bit           D7             D6              D5              D4              D3              D2             D1              D0
 Name                                                                 CLK4_PHOFF[6:0]
  Type          R/W            R/W             R/W             R/W             R/W            R/W             R/W             R/W
Reset value = 0000 0000

 Bit            Name                                                           Function
  7           Reserved           Only write 0 to this bit.
 6:0     CLK4_PHOFF[6:0] Clock 4 Initial Phase Offset.
                                 CLK4_PHOFF[6:0] is an unsigned integer with one LSB equivalent to a time delay of
                                 Tvco/4, where Tvco is the period of the VCO/PLL associated with this output.


Register 170. CLK5 Initial Phase Offset


   Bit           D7             D6              D5              D4              D3              D2             D1              D0
 Name                                                                 CLK5_PHOFF[6:0]
  Type          R/W            R/W             R/W             R/W             R/W            R/W             R/W             R/W
Reset value = 0000 0000

 Bit            Name                                                           Function
  7           Reserved           Only write 0 to this bit.
 6:0     CLK5_PHOFF[6:0] Clock 5 Initial Phase Offset.
                                 CLK5_PHOFF[6:0] is an unsigned integer with one LSB equivalent to a time delay of
                                 Tvco/4, where Tvco is the period of the VCO/PLL associated with this output.




         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com            59
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619

Register 177. PLL Reset


    Bit           D7             D6              D5              D4              D3              D2             D1              D0

  Name      PLLB_RST                        PLLA_RST

   Type         R/W             R/W             R/W             R/W             R/W            R/W             R/W             R/W

Reset value = 0000 0000

  Bit        Name                                                           Function

   7      PLLB_RST PLLB_Reset.
                          Writing a 1 to this bit will reset PLLB. This is a self clearing bit.

   6       Reserved       Leave as default.

   5      PLLA_RST PLLA_Reset.
                          Writing a 1 to this bit will reset PLLA. This is a self clearing bit.

  4:0      Reserved       Leave as default.


Register 183. Crystal Internal Load Capacitance


    Bit           D7             D6              D5              D4              D3              D2             D1              D0

  Name             XTAL_CL[1:0]

   Type         R/W             R/W             R/W             R/W             R/W            R/W             R/W             R/W

Reset value = 11xx xxxx

  Bit         Name                                                           Function

  7:6     XTAL_CL[1:0] Crystal Load Capacitance Selection.
                             These 2 bits determine the internal load capacitance value for the crystal. See the Crystal
                             Inputs section in the Si5351 data sheet.
                             00: Reserved. Do not select this option.
                             01: Internal CL = 6 pF.
                             10: Internal CL = 8 pF.
                             11: Internal CL = 10 pF (default).

  5:0       Reserved         Bits 5:0 should be written to 010010b.




60        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
                                                                                                                       AN619

Register 187. Fanout Enable


   Bit           D7              D6             D5              D4              D3              D2              D1             D0

 Name      CLKIN_FA- XO_FA-                 Reserved        MS_FA-                                   Reserved
           NOUT_EN NOUT_EN                                 NOUT_EN

  Type          R/W             R/W            R/W             R/W             R/W             R/W             R/W            R/W

Reset value = xxxx xxxx

  Bit        Name                                                           Function

   7      CLKIN_FA-         Enable fanout of CLKIN to clock output multiplexers. Set this bit to 1b.
          NOUT_EN

   6        XO_FA-          Enable fanout of XO to clock output multiplexers. Set this bit to 1b.
           NOUT_EN

   5       Reserved         Reserved.

   4        MS_FA-          Enable fanout of Multisynth0 and Multisynth4 to all output multiplexers. Set this bit to 1b.
           NOUT_EN




         Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com            61
Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
AN619
DOCUMENT CHANGE LIST                                                     Updated Register 36 description
                                                                      Revision 0.7 to Revision 0.8
Revision 0.1 to Revision 0.2
                                                                         Updated to include ClockBuilder Pro
   Corrected Typos
                                                                         Clarified 10-MSOP and 20-QFN package coverage
    Feedback fractional divide value can be up to 90 (not
      900).                                                              Added reference to AN1234 for 16-QFN
    Corrected miscellaneous typographical errors.
                                                                          Programming Instructions
 Added note to “3.2. Feedback Multisynth Divider                        Updated Section "8.1. Register Map Summary" on
  Equations” to set MSNB a + b/c divide ratio such that                   page 10.
  c = 106 when using VCXO equations in this                              Cleaned up register descriptions
  document.
 Added Figure 2.

Revision 0.2 to Revision 0.3
 Updated first bullet in “Section 5. Configuring Spread
  Spectrum Register Parameters.”
 Updated “Section 8.1 Register Map Summary.”
 Updated Register 183.

Revision 0.3 to Revision 0.4
 Corrected typographic error in maximum spread
  spectrum percentage for center spread on page 8.
 Added rounding operator for up spread depth
  calculation on page 9.
 Corrected register description errata on pages 11,13,
  31, and 32.
Revision 0.4 to Revision 0.5
 Updated “8.1. Register Map Summary”.
 Updated “6. Configuring Initial Phase Offset Register
  Parameters”.
 Corrected Register 16 description.

Revision 0.5 to Revision 0.6
   Updated “8.1. Register Map Summary”.
   Corrected Register 161 description.
Revision 0.6 to Revision 0.7
   Corrected Typo in Section “3.1.2. CMOS Clock
    Source”
   Corrected Typo in Section “3.2. Feedback Multisynth
    Divider Equations” Now c = 10^6
   Removed Section 3.3. Miscellaneous PLL
    Parameters.
   Fixed minor typos in Section “5. Configuring Spread
    Spectrum Register Parameters”
   Corrected Register 36 fields in Section "“8.1.
    Register Map Summary”.
   Updated Register 0 description to include the
    Revision ID.
   Fixed Register 32 Register Name


62        Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
 Rev. 0.8 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 23, 2021
     ClockBuilder Pro
     Customize Skyworks clock generators,
     jitter attenuators and network
     synchronizers with a single tool. With
     CBPro you can control evaluation
     boards, access documentation, request
     a custom part number, export for
     in-system programming and more!


     www.skyworksinc.com/CBPro




                    Portfolio                           SW/HW                               Quality                     Support & Resources
         www.skyworksinc.com/ia/timing        www.skyworksinc.com/CBPro           www.skyworksinc.com/quality         www.skyworksinc.com/support


Copyright © 2021 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the
information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer.
Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation,
products, services, speciﬁcations or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or
information and shall have no responsibility whatsoever for conﬂicts, incompatibilities, or other diﬃculties arising from any future changes.

No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability
for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or
materials, except as may be provided in Skyworks’ Terms and Conditions of Sale.

THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR
OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY
INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR
COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR
ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT
LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT
OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks
products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such
applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale.

Customers are responsible for their products and applications using Skyworks products, which may deviate from published speciﬁcations as a result of
design defects, errors, or operation of products outside of published parameters or design speciﬁcations. Customers should include design and operating
safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any
equipment resulting from the use of Skyworks products outside of Skyworks’ published speciﬁcations or parameters.

Skyworks, the Skyworks symbol, Sky5®, SkyOne®, SkyBlue™, Skyworks Green™, Clockbuilder®, DSPLL®, ISOmodem®, ProSLIC®, and SiPHY® are trademarks or
registered trademarks of Skyworks Solutions, Inc. or its subsidiaries in the United States and other countries. Third-party brands and names are for
identiﬁcation purposes only and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at
www.skyworksinc.com, are incorporated by reference.


                          Skyworks Solutions, Inc. | Nasdaq: SWKS | sales@skyworksinc.com | www.skyworksinc.com
                            USA: 781-376-3000 | Asia: 886-2-2735 0399 | Europe: 33 (0)1 43548540 |
